Adapter Mounting Instructions

for Gleaner Combines

PREPARING THE ADAPTER

1. Install upper beam (1) (from adapter package)

onto the adapter frame with two 1/2 x 1 flange
bolts (E) (one each side) and four 1/2 x 1
carriage bolts (C) and flange nuts (D) (two
each side).
NOTE: For attachment to adapter at top beam,
engage carriage bolts (C) in keyhole slots.

2. Attach left member (2) with three 1/2 x 1

carriage bolts (C), one 1/2 x 1 flange bolt (E)
and flange nuts (D). Repeat at right side.

3. Insert lower latch support (3) into oblong slot in

adapter frame as shown. Secure with 5/8 x
1-1/2 carriage bolt (F), flat washer (G) and nut
(H). Repeat at other side.

4. Install shields and other components.

A

BOLT – round head, sq. neck, 3/8 NC x 3/4 in.

B

NUT - lock, smooth flange, 3/8 NC dist. thread

C

BOLT - round hd. short sq. nk, 1/2 NC x 1"

D

NUT - lock, smooth flange, 1/2 NC dist. thread

E

BOLT - flange head, 1/2 NC x 1 inch

F

BOLT - rnd. hd. sq. neck, 5/8 NC x 1-1/2 inch

G

WASHER - flat, 21/32 inch I.D.

H

NUT - lock, 5/8 NC distorted thread

L

BOLT - hex head, 5/8 NC x 1-1/2 inch

R

BOLT - hex head, 3/8 NC x 1-1/2 inch

S

WASHER - flat, 13/32 inch I.D.

T

BOLT – round head, sq. neck, ½ NC x 1-1/4”

INSTALL ADAPTER COMPLETION PARTS