Prescolite 93147 User Manual

Instruction sheet

Advertising
background image

Instruction

Sheet

www

.prescolite.com

• Prescolite

TollFree

Technical Support

1.888.PRS.4TEC

• Hours: 8am - 5pm ET

101 Corporate Drive • Spartanburg, SC 29303

With representatives offices in principal cities throughout North America.

Copyright 2005, 08/05 revision, All Rights Reserved - Printed in U.S.A.

Part No. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .03379300

Instruction

Sheet

INSTALLATION INSTRUCTIONS

RECESSED AISLE LIGHT 93047, 93147

1.

Install the conduit (by others) to align with tapped hole to be used in the

J-Box

2. Remove faceplate.
3. To install housing for concrete pour, fasten mounting brackets to

reinforcing steel or other structure. For drywall construction, frame in

the housing as required. The housing should be flush with the finished

wall surface for both wet and drywall construction (Fig. 2).

4. Remove the ballast cover plate and the J-Box cover plate.
5. Remove J-Box cover plate. Remove appropriate knockout and

assemble appropriate connector for the supply wire used. Connect

ground wires to green ground leads. Connect white (common) to white

(leads). Connect power supply (line) to the transformer leads marked

120V, 208V, 240V, 277V, 347V, or 480V, dependant or line voltage and

COM. All disconnected transformer leads must be capped off. Reinstall

J-Box cover.

WARNING: DO NOT pinch wires between J-Box/ballast cover and

J-Box. Consult a Qualified Electrician for all other options that

require other wiring configurations.

Replace the ballast cover plate.

6. Reassemble the faceplate.

“J” BOX COVERPLATE

RETAINED WITH

(2) SCREWS

Figure 1

BALLAST COVER

“J” BOX

ADJUSTABLE MTG. BRACKET (2)

FURNISHED IN PACKET

FACEPLATE

GASKET

TYPICAL

OVERLAP TRIM

MOUNTING

TYPICAL FOR

WET OR DRY

CONSTRUCTION

DRY

CONSTRUCTION

FACEPLATE

SCREWS (2)

HOUSING

CAUTION: If through branch circuit conductors are

pulled through the junction box, please use extreme

caution so as not to damage or disconnect thermal

protection wiring. Do not modify or defeat the thermal

protection circuit designed into the fixture.

Figure 2

WET

CONSTRUCTION

IMPORTANT SAFETY INFORMATION. READ AND FOLLOW ALL SAFETY INSTRUCTIONS. Follow label information

and instructions concerning Wet or Damp Locations, installation near combustible materials, insulation, building materials,

and proper lamping. Do not install in areas subject to combustible vapors or gases. Before wiring to power supply and

during servicing or relamping, turn off power at fuse or circuit breaker. All servicing or relamping must be performed by

qualified service personnel. Product must be grounded to avoid potential electric shock or other potential hazard.

Product must be mounted in locations and at heights and in a manner consistent with its intended use, and in

compliance with the National Electrical Code and local codes. The use of accessory equipment not recommended by

the manufacturer or installed contrary to instructions may cause an unsafe condition. Do not block light emanating from

product in whole or part, as this may cause an unsafe condition. Do not allow items such as drapes, curtains, screens or

the like to come into contact with the product or to block light from the product, as this may cause an unsafe condition.