INSTALLATION INSTRUCTIONS

CAT. NO. D4

Reflector

Adjustable

Mounting

Bracket

CAUTION: DO NOT ATTEMPT TO MODIFY OR REWIRE FACTORY-INSTALLED WIRING ON THE FIXTURE. SAFETY AND PROPER

OPERATION OF THE FIXTURE DEPEND ON THE INTEGRITY OF THE WIRING.

SAVE THESE INSTRUCTIONS.

1. Bend brackets as shown in Detail “A”. Install the

fixture in the ceiling using mounting channels or bar

hangers (B6, B24, or by others) placed in the

adjustable mounting brackets. Mount the fixture in

the ceiling so that the weight of the fixture is

supported by the mounting channel or bar and/or

hanger wires secured to the building structure.

2. Adjust the fixture so the bottom edge of the plaster

flange opening is flush with the finished ceiling line

and in alignment with adjacent fixtures. Secure

mounting brackets by tightening wing nuts on either

side of the fixture.

3. Remove and discard the wire twist around the

J-Box covers. Remove J-Box cover plate.

Remove appropriate knockout and assemble

certified conduit connector for the supply wire used.

Connect supply ground wire to fixture ground wire.

Connect common supply wire to white fixture wire.

Connect 120V or 277V supply wire to the respec-

tive 120V or 277V fixture wire. Use certified wire

nuts. Reinstall J-Box cover.
WARNING: DO NOT pinch wires between

J-Box/ballast cover and J-Box. Consult a

Qualified Electrician for all other options that

require other wiring configurations.

4. Install reflector after all ceiling installation and

finishing work is complete.
Insert sides of heatsink spring into reflector neck

clearance slots, then twist heatsink and push down

until desired position on the reflector is obtained.

Align heatsink spring with appropriate reflector

slots. Heatsink will lock into place, but may be

readjusted by twisting and sliding the heatsink into

another position. Do NOT use the reflector neck

clearance slots as a final installation position for the

heatsink.

5. Push reflector into the plaster flange until the

reflector is flush against the ceiling.

6. Install the proper lamps (by others).
7. For housing CAT. NO. D4MR, install a lamp marked

“Suitable for use in open luminaires” unless used in

combination with Prescolite CAT. NO. 2MLH.

8. To install the accessory CAT. NO. 2MLH, first have

the reflector installed in the housing. Separate the

halves of 2MLH by twisting them apart. Remove

the lens retainer wire. Place the maximum quantity

of two (2) optical accessories and the MR16 lamp

into the bottom half of 2MLH. Replace the lens

retainer wire over the edge of the MR16 lamp.

Combine the halves of 2MLH by twisting them

together. Finally, insert the MR16 lamp pins into

the Leviton MR16 lampholder. Replace removable

parts after servicing.

Wing Nut

NOTE: Brackets are

supplied flat. To ensure

proper alignment, bend

brackets in line with

marks on flange as

shown in Detail A.

DETAIL A

2MLH

J-Box

Transformer/

Ballast

Plate

Bend Brackets in

Line with Marks

on Flange.

NOTE: Remove (3) Grip

Clip Springs before

installing a Wallwash

Trim.

Heatsink

Plaster

Flange

J-Box

Cover

IMPORTANT SAFETY INFORMATION. READ AND FOLLOW ALL SAFETY INSTRUCTIONS. Follow label information

and instructions concerning Wet or Damp Locations, installation near combustible materials, insulation, building materials,

and proper lamping. Do not install in areas subject to combustible vapors or gases. Before wiring to power supply and

during servicing or relamping, turn off power at fuse or circuit breaker. All servicing or relamping must be performed by

qualified service personnel. Product must be grounded to avoid potential electric shock or other potential hazard.

Product must be mounted in locations and at heights and in a manner consistent with its intended use, and in

compliance with the National Electrical Code and local codes. The use of accessory equipment not recommended by

the manufacturer or installed contrary to instructions may cause an unsafe condition. Do not block light emanating from

product in whole or part, as this may cause an unsafe condition. Do not allow items such as drapes, curtains, screens or

the like to come into contact with the product or to block light from the product, as this may cause an unsafe condition.

See Label for

Lamp Positioning:

Heatsink

Spring

Media Holder Bottom

Lens Retainer Ring

Media Holder Top

Advertising