Prescolite RHD802 User Manual

Instruction sheet, Installation instructions

Advertising
background image

Instruction

Sheet

Part No........................................................93010491

IMPORTANT SAFETY INFORMATION. READ AND FOLLOW ALL SAFETY INSTRUCTIONS. Follow label information and

instructions concerning Wet or Damp Locations, installation near combustible materials, insulation, building materials, and

proper lamping. Do not install in areas subject to combustible vapors or gases. Before wiring to power supply and during

servicing or relamping, turn off power at fuse or circuit breaker. All servicing or relamping must be performed

by qualified service personnel. Product must be grounded to avoid potential electric shock or other

potential hazard. Product must be mounted in locations and at heights and in a manner consistent with

its intended use, and in compliance with the National Electrical Code and local building codes. The use

of accessory equipment not recommended by the manufacturer or installed contrary to instructions may cause an unsafe

condition. Do not block light emanating from product in whole or part, as this may cause an unsafe condition. Do not allow

items such as drapes, curtains, screens or the like to come into contact with the product or to block light from the product, as

this may cause an unsafe condition.

INSTALLATION INSTRUCTIONS

RHD602 & RHD802

www

.prescolite.com

Prescolite T

ollFree T

echnical Suppor

t

1.888.PRS.4TEC

Hours: 8am - 5pm ET

1.) Before installing trim, remove stopping screw and loosen socket locking screws (2) and push socket up into heat sink until

it stops.

2.) Loosen yoke adjustment screws (2) and adjust yoke to proper height as shown in diagram below.
3.) Loosen upper trim mounting screws (2) and install upper reflector by aligning key hole slots over mounting screws and rotating

reflector until it stops and tighten screws firmly.

4.) Install appropriately rated lamp as shown on the relamp label found on the inside of upper trim.
5.) Install lower reflector assembly by pushing it up through the plaster frame until flange is firmly against ceiling surface.
6.) Make sure top of the lower reflector assembly is inside the lower edge of the upper reflector. If a gap is visible adjust yoke

down until no gap is visible.

701 Millennium Blvd, Greenville, SC 29607

With representatives offices in principal cities throughout North America.

Copyright 2007,

07/12/07, All Rights Reserved - Printed in U.S.A.

RHD602 - 6”

RHD802 - 7”

Lower

Reflector

Assembly

Yoke

Stopping Screw

Heat Sink

Socket Position

Locking Screw (2)

Reflector

Mounting

Screw (2)

Upper

Reflector

Relamp Label

Yoke Adjustment

Screw (2)

wARNING: DO NOT ENERGIzE LAMPS If ANy GAP BETwEEN UPPER AND LOwER TRIMS

ExISTS, AS THIS wILL RESULT IN A HIGH RISk Of fIRE IN THE CASE Of A LAMP fAILURE

Ceiling Surface

Advertising
This manual is related to the following products: