Instruction

Sheet

Part No........................................................930017587

IMPORTANT SAFETY INFORMATION. READ AND FOLLOW ALL SAFETY INSTRUCTIONS. Follow label information and instructions concerning Wet or Damp

Locations, installation near combustible materials, insulation, building materials, and proper lamping. Do not install in areas subject to combustible vapors or gases.

Before wiring to power supply and during servicing or relamping, turn off power at fuse or circuit breaker. All servicing or relamping must be performed

by qualified service personnel. Product must be grounded to avoid potential electric shock or other potential hazard. Product must be

mounted in locations and at heights and in a manner consistent with its intended use, and in compliance with the National Electrical

Code and local building codes. The use of accessory equipment not recommended by the manufacturer or installed contrary to instructions may cause an

unsafe condition. Do not block light emanating from product in whole or part, as this may cause an unsafe condition. Do not allow items such as drapes, curtains,

screens or the like to come into contact with the product or to block light from the product, as this may cause an unsafe condition.

INSTALLATION INSTRUCTIONS

6C3FC, 6B3FC, 6C3STFC, 6B3STFC

6C3AC, 6B3AC, 6C3STAC, 6B3STAC REFLECTOR

www

.prescolite.com

Prescolite T

ollFree T

echnical Suppor

t

1.888.PRS.4TEC

Hours: 8am - 5pm ET

A. Lamp Adjustment Prior

To Trim Installation:

1. Turn power off.

2. Loosen horizontal and vertical locking

Thumbscrews as shown, (1) & (2).

3. Remove Lamp Holder (3). Install lamp into

Socket (4). Re-install Lamp Holder into Lamp

Mounting Plate (5).

4. Rotate Lamp Adjusting Mechanism (6)

to desired vertical angle and horizontal

position by inserting a standard screwdriver

into slots as shown.(6)

NOTE: Vertical

increment indicator numbers can

be used to pre-adjust the vertical

angle if desired. NOTE: Set lamp

position at 0º for FC trims, or at

specified angle shown on trim label

for AC trims. Rotate thumbscrew (2)

clockwise to lock in place.

B. Trim Installation:

1. Remove Screw (10), pull Safety Cable (7)

through opening in Plaster Frame and attach

to Trim as shown using screw (10).

2. Squeeze the two Torsion Springs (8) together

and insert ends into slots on both Brackets

(9) as shown.

3. Push Trim towards ceiling until the Torsion

Springs force the Trim against the ceiling

line.

C. Final Adjustment:

1. Make final horizontal adjustment by

holding outer flange on Trim and rotating

horizontally.

NOTE: If necessary, pull

the flange away from the ceiling

slightly before rotating.

D. Locking Horizontal Aim:

NOTE: Turn power off and allow

lamp to cool if necessary.

1. Pull Trim away from ceiling, reach into

housing and rotate Thumb Screw (1)

clockwise to lock in place.

2. Push Trim back towards ceiling until seated

against ceiling.

WARNING: This product contains chemicals known to the State of California to cause cancer, birth defects and/or

other reproductive harm. Thoroughly wash hands after installing, handling, cleaning, or otherwise touching this

product.

CAUTION: DO NOT ATTEMPT TO MODIFY OR REWIRE FACTORY-INSTALLED WIRING ON THE FIXTURE. SAFETY

AND PROPER OPERATION OF THE FIXTURE DEPEND ON THE INTEGRITY OF THE WIRING.

701 Millenium Boulevard • Greenville, SC 29607

With representatives offices in principal cities throughout North America.

Copyright 2008, 7/29/08 All Rights Reserved - Printed in U.S.A.



426&&;&5034*0/

413*/(4"44)08/











-0$"5&53*.'&"563&

"8":'30.4*%&8*5)

4"'&5:$"#-&















426&&;&413*/(50(&5)&3"4

4)08/"/%*/4&35*/4-054









FC

(FULL CUT)

AC

(ANGLE CUT)

Advertising
This manual is related to the following products: