Instruction

Sheet

INSTALLATION INSTRUCTIONS
CORD SUSPENDED CANOPIES

Fig. 3

STRAIN RELIEF INSTALLATION

Running Thread

Strain Relief

(install above strap)

Canopy

Strap

(mount on outlet box)

Knurled Nut
(to be tight
against canopy)

Bushing

Cord

Canopy A-101

1. Slide shade on cord if required before mounting canopy.

See instructions packed with shade.

2. Mount strap on outlet box.

3. Pass cord thru bushing, running thread, knurled nut, canopy and strap (Fig. 3).

Install starin relief and determine proper cord length by sliding strain relief to
desired position. (Fig. 4).

4. Make electrical connections. Connect ground wires to green ground leads.

Connect white (common) to white leads. Connect power supply (line) to black
leads. (see wiring diagram).

WARNING: DO NOT pinch wires. Consult a Qualified Electrician for all
other options that require other wiring configurations.

5. Screw running thread into strap. Adjust knurled nut so that canopy will be

clamped when bushing is tight on end of running thread and canopy is flush
against ceiling.

Fig. 4

IMPORTANT SAFETY INFORMATION. READ AND FOLLOW ALL SAFETY INSTRUCTIONS. Follow label information
and instructions concerning Wet or Damp Locations, installation near combustible materials, insulation, building materials,
and proper lamping. Do not install in areas subject to combustible vapors or gases. Before wiring to power supply and
during servicing or relamping, turn off power at fuse or circuit breaker. All servicing or relamping must be performed by
qualified service personnel. Product must be grounded to avoid potential electric shock or other potential hazard.
Product must be mounted in locations and at heights and in a manner consistent with its intended use, and in
compliance with the National Electrical Code and local codes.
The use of accessory equipment not recommended by
the manufacturer or installed contrary to instructions may cause an unsafe condition. Do not block light emanating from
product in whole or part, as this may cause an unsafe condition. Do not allow items such as drapes, curtains, screens or
the like to come into contact with the product or to block light from the product, as this may cause an unsafe condition.