INSTALLATION INSTRUCTIONS

CAT. NO. 37G-TP-1, 2 & 4

1. Install the housing by nailing the mounting

brackets on the housing to the frame support as

shown in Fig. 1 or frame in the housing as

desired for wet or dry wall construction.

2. Assemble the gasket and trim ring to the housing

with (4) 6-32 x 1/4 flat head screws (provided in

packet) as shown in Fig. 3. Adjust the mounting

brackets to locate the housing as required for

flush or profile trim, Fig. 2.

3. Install the conduit (by others) to align with the 1/2

NPT tapped holes in the J-Box as shown, remove

the (4) screws retaining the socket mounting plate

and lift out.

IMPORTANT - WHEN INSTALLED IN BRICK OR

BRICK VENEERED WALLS, THE RECESSED

PORTION OF THE HOUSING MUST BE

COATED WITH ASPHALTUM OR SIMILAR

PROTECTIVE MATERIAL. SOME TYPES OF

BRICKS RETAIN MOISTURE AND OTHER

SUBSTANCES THAT CAN DAMAGE THE

HOUSING. DO NOT CLEAN BRICK WALL WITH

ACIDS WHILE FIXTURE IS IN PLACE.

4. When installed in concrete pour or mortar and in a

situatiuon where direct water exposure is

frequent, the concrete or mortar is to be suitably

treated with a water sealing or repelling agent to

insure that the fixture housing does not remain

continuously wet.

Support Frame

(By Others)

Profile Trim

(wet or drywall

construction)

Profile or Flush Trim

Fig. 2

Thermal

Protector

Conduit

Entry

Adjustable

Mounting

Bracket (2)

Housing

Thermal

Protector

Conduit

(By Others)

Housing

Ground Screw

J-Box

Housing Installation

Fig. 1

Adjustable Mounting

Bracket (2)

Fastener (Nail)

(By Others)

Flush Trim

(Wet Construction)

J-Box

IMPORTANT SAFETY INFORMATION. READ AND FOLLOW ALL SAFETY INSTRUCTIONS. Follow label information

and instructions concerning Wet or Damp Locations, installation near combustible materials, insulation, building materials,

and proper lamping. Do not install in areas subject to combustible vapors or gases. Before wiring to power supply and

during servicing or relamping, turn off power at fuse or circuit breaker. All servicing or relamping must be performed by

qualified service personnel. Product must be grounded to avoid potential electric shock or other potential hazard.

Product must be mounted in locations and at heights and in a manner consistent with its intended use, and in

compliance with the National Electrical Code and local codes. The use of accessory equipment not recommended by

the manufacturer or installed contrary to instructions may cause an unsafe condition. Do not block light emanating from

product in whole or part, as this may cause an unsafe condition. Do not allow items such as drapes, curtains, screens or

the like to come into contact with the product or to block light from the product, as this may cause an unsafe condition.