• Prescolite

TollFree

Technical Support

1.888.PRS.4TEC

• Hours: 8am - 5pm ET

101 Corporate Drive • Spartanburg, SC 29303

With representatives offices in principal cities throughout North America.

Copyright 2005, 08/05 revision, All Rights Reserved - Printed in U.S.A.

Part No. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .157900100

Instruction

Sheet

INSTALLATION INSTRUCTIONS

FOR AKTSL “L”/STRAIGHT CONNECTOR
FOR USE WITH PRESCOLITE ONE/TWO CIRCUIT ARCHITRACK SYSTEM ONLY
READ INSTALLATION INSTRUCTIONS BEFORE INSTALLING THE TRACK SYSTEM
SAVE INSTRUCTIONS FOR REFERENCE WHEN MAKING ADDITIONS TO OR CHANGES IN THE TRACK SYSTEM.

INSTALLATION

1. Refer to PRESCOLITE AKT series track for track installation instructions

2. Loosen retaining screw at ends of connector.

3. Align connector with pre-mounted track rail. Insert and press together. Tighten retaining screw.

4. Align next piece of track with L-connector, insert and press together, secure track to ceiling. Refer to track installation instructions.

Repeat for remaining track rails.

5. When used as a power feed connectors refer too one and two circuit diagrams below.

6. Note

Connector is supplied as a 90º connector to change. To a straight connector remove 90º cover, straighten connector, secure with

straight cover provided.

POWER FEED WIRING DIAGRAMS

IMPORTANT SAFETY INFORMATION. READ AND FOLLOW ALL SAFETY INSTRUCTIONS. Follow label information

and instructions concerning Wet or Damp Locations, installation near combustible materials, insulation, building materials,

and proper lamping. Do not install in areas subject to combustible vapors or gases. Before wiring to power supply and

during servicing or relamping, turn off power at fuse or circuit breaker. All servicing or relamping must be performed by

qualified service personnel. Product must be grounded to avoid potential electric shock or other potential hazard.

Product must be mounted in locations and at heights and in a manner consistent with its intended use, and in

compliance with the National Electrical Code and local codes. The use of accessory equipment not recommended by

the manufacturer or installed contrary to instructions may cause an unsafe condition. Do not block light emanating from

product in whole or part, as this may cause an unsafe condition. Do not allow items such as drapes, curtains, screens or

the like to come into contact with the product or to block light from the product, as this may cause an unsafe condition.

INSTALLATION INSTRUCTIONS

ARCHITRAK

®

SYSTEM

RETAINING SCREW

FACTORY WIRING DIAGRAM

WIRE DIAGRAM 1-CIRCUIT
WIRE HOT WIRE TO L-1

NEUTRAL TO N-1, CONNECT

GROUND WIRE TO GROUND

SCREW.

WIRE DIAGRAM 1-CIRCUIT

WIRED FOR 2-CIRCUITS.
WIRE HOT WIRE TO L-1.

NEUTRAL TO N-1, BLACK

JUMPER WIRE TO L-1 AND

L-2, WHITE JUMPER WIRE

TO N-1 AND N-2, CONNECT

GROUND WIRE TO GROUND

SCREW.

WIRE DIAGRAM 2-CIRCUITS
CIRCUIT 1, WIRE HOT WIRE TO

L-1, NEUTRAL WIRE TO N-1,

GROUND WIRE TO GROUND TERMINAL,

CIRCUIT 2, WIRE HOT WIRE

TO L-2, NEUTRAL WIRE TO N-2,

GROUND WIRE TO GROUND TERMINAL.

NOTE: L-1, L-2 BRASS COLORED TERMINALS

N-1, N-2 NICKEL COLORED TERMINALS

JUMPER WIRES, USE 12GA.

STRANDED UL/CSA LISTED

90 DEGREE WIRE.

WHEN WIRED IN THIS

CONFIGURATION ONE

SET OF BUSS BARS

WILL NOT BE ENERGIZED.