Prescolite TA30B/C/G & BF User Manual

Instruction sheet, Installation instructions ta30b/c/g & bf, Prs.4tec

Advertising
background image

www

.prescolite.com

• Prescolite

TollFree

Technical Support

1.888.PRS.4TEC

• Hours: 8am - 5pm ET

101 Corporate Drive • Spartanburg, SC 29303

With representatives offices in principal cities throughout North America.

Copyright 2005, 08/05 revision, All Rights Reserved - Printed in U.S.A.

Part No. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .05489600

Instruction

Sheet

INSTALLATION INSTRUCTIONS

TA30B/C/G & BF

1. Install lampholder from housing into mounting hole in top of yoke.
2. Install lamp. Use up to 75W PAR-30, 75W R-30 lamps.

3. To install trim into housing, squeeze torsion spring legs together

and place them into torsion spring brackets as shown. Push trim

up into housing aperture until flange seats flush against ceiling.

Lampholder

Yoke

Lamp (by others)

Trim Flange

Torsion Spring

Hex Socket

Cap Screw

Allen Wrench

Torsion Spring

Bracket

INSTALLING THE TRIM

AIMING THE LAMP

Note: Trim removal is not required for relamping.

1. Trim may be manually rotated and yoke tilted from vertical to obtain desired aiming angle.

Caution: Before making lamp angle adjustment, turn off fixture and allow lamp to cool.

Note: For vertical aiming, unlock yoke by loosening hex socket cap screw with a

3

/

32

Allen wrench. (See item 2. below for tightening and loosening).

2. When desired aiming angle is accomplished, lock yoke in place by tightening hex socket cap screw located on inside of

cone or baffle: turn wrench clockwise to tighten, counterclockwise to loosen.

Note: Trim or lamp removal is not required for adjustment.

IMPORTANT SAFETY INFORMATION. READ AND FOLLOW ALL SAFETY INSTRUCTIONS. Follow label information

and instructions concerning Wet or Damp Locations, installation near combustible materials, insulation, building materials,

and proper lamping. Do not install in areas subject to combustible vapors or gases. Before wiring to power supply and

during servicing or relamping, turn off power at fuse or circuit breaker. All servicing or relamping must be performed by

qualified service personnel. Product must be grounded to avoid potential electric shock or other potential hazard.

Product must be mounted in locations and at heights and in a manner consistent with its intended use, and in

compliance with the National Electrical Code and local codes. The use of accessory equipment not recommended by

the manufacturer or installed contrary to instructions may cause an unsafe condition. Do not block light emanating from

product in whole or part, as this may cause an unsafe condition. Do not allow items such as drapes, curtains, screens or

the like to come into contact with the product or to block light from the product, as this may cause an unsafe condition.

Advertising