Pro1 tip technician setup menu, Selecting heat or cool, Tech setup steps – Pro1 T771 Installation manual User Manual

Page 7: Swing, Heat or cool, Temperature setpoint limit

Advertising
background image

Temperature swing, sometimes called differetial or cycle rate, can be customized for this individual

application. For most applications choose a swing setting that is as long as possible without making

the occupants uncomfortable.

PRO1 Tip

Technician Setup Menu

This thermostat has a technician setup menu

for easy installer configuration. To set up the

thermostat for your particular application:

Use the or keys to change the

options below and the

LIGHT key to move

from one step to another.

Hold down and key together

for 3 seconds.

Configure the installer options as desired

using the table below.

1.

2.

3.

4.

Selecting Heat or Cool

Set system switch to on.

Hold down and key
for 3 seconds to bring up the current mode.

Use or to select the mode.

Wait 10 sec for the thermostat to return to
normal operation.

Adjustment Options

Factory Default Settings

Tech Setup Steps

LCD Will Show

The swing setting, often called “cycle rate”,

“differential” or “anticipation” is adjustable.

A smaller swing setting will cause more

frequent cycles and a larger swing setting will

cause fewer cycles.

(reference the

Technician Setup Menu

steps above for how to enter this Menu)

The swing setting is adjustable

from ±0.4°F to ±2°F. For example:

For example, a swing setting of 0.5 will turn

the system on and off at approximately 0.5º

away from the setpoint.

Only the swing for the selected mode

(Heat of Cool) is displayed in the Menu.

Swing

0.4 Heat and 0.5 Cool

This feature allows the installer to

configure the thermostat for Heat only

or Cool only operation.

(reference the

Selecting Heat or Cool

steps above for how to enter this Menu)

Heat or Cool

Heat

Heat or Cool

Use the or key to select the

maximum heat setpoint or the minimium cool

depending on the selected mode (Heat of Cool).

25º for cool and 90º for heat

This feature allows you to set a maximum heat

setpoint value. The setpoint temperature cannot

be raised above this value.

Temperature Setpoint Limit

Set system switch to off.