ASSEMBLY QUICK VIEW (RD-106, follow the photo below, for RD-100 filters are already installed)

Carbon Carbon Sediment


1. Remove plastic wrap on the filters (for RD-106)
2. Insert the filters as shown above.

1. Put upper portion of the unit on top of the filter housing
2. Screw on the filter housing

vertically to the filter housing cap

by hand
3. Then use filter housing wrench to tighten the each housing

3 ways to connect to water supply: (1) Connect to faucet, (2) Connect to garden hose or laundry room hose, (3)

Install under the sink and connect to cold water supply

Connect to faucet: You can use the diverter valve to connect to the aerator part of your faucet.

1. Unscrew the tip or the aerator part of your faucet.
2. Connect tubing to the barb connection of the diverter valve by pushing in the tubing
3. Make sure the diverter valve threaded portion has a small O-ring in place.
4. Screw on the diverter valve to the faucet tip. Use pliers if necessary.
5. Connect the other end of the tubing to the RO+DI system
6. Turn on your kitchen faucet all the way up, cold water. The water should come out of

the valve like regular faucet water. Then turn the lever 90 degree to divert water to the
RO+DI system.

7. Then follow the picture below for the other tubing connection. You can put the drain

line to the sink. It is not required to plumb the drain, just let it flow to the sink.

8. NOTE: The size provided is the most common size. If your faucet does not fit, you

can buy converter at local hardware store or choose other methods of connecting it.


Connect to garden hose or laundry room hose

1. You can connect the ¾” garden hose adapter directly to the hose valve or to hose.
2. Just screw on the adapter directly to the hose or hose valve. Use pliers if necessary.
3. The other end of the adapter is a Quick-connect fitting ¼”. So just push in the ¼”

tubing about ½” into the fitting, then it will seal itself.

4. Then for other tubing connection, please refer to the picture shown next page. The

drain line can just run to open drain or to the laundry room drain.

5. You can also use a hose Y-connector to connect to the hose valve to have two outlets,

so one for the system and one for your laundry room washer.