RKI Instruments 65-2400RK-05 User Manual

Overview, Specifications

Advertising
background image

RKI Instruments, Inc. • 1855 Whipple Rd. • Hayward, CA 94544 • (510) 441-5656 • 1

Combustible Gas Transmitter 65-2400RK-05

Overview

This detection insert describes the combustible gas transmitter. This insert also describes
how to install, start up, maintain, and calibrate the transmitter. A parts list at the end of
this insert lists replacement parts and accessories for the combustible gas transmitter.

Specifications

WARNING: Do not use this product in a manner not specified in this instruction

manual.

Table 1 lists specifications for the combustible gas transmitter.

NOTE: The following symbol on the detector label is a caution to the user to refer to this

documentation for installation and operation instructions:

Table 1: Specifications

Target Gas

Combustible gas

Area Classification

Explosionproof for Class I, Groups B, C, and D

Sampling Method

Diffusion

Signal Output

4 to 20 mA

Detection Range

0 to 100% LEL

Response Time

90% in 45 seconds

OperatingTemperature

-40°F to 185°F (-40°C to 85°C)

!