Chapter 5. Appendix

5.1

Factory Settings

Factory setting of the modem COM port under

Config Mode and Normal Mode

is:

Data bits = 8
Parity = none
Stop bits = 1
Baud = 115200 bps
Flow control = none

5.2

SMS Command for Remote Control

5.2.1 SMS Commands Structure

M1000 Pro V2 supports remote configuration and remote modem status reading via SMS.
An SMS command has following structure: Password: cmd
 Password: SMS control password is configured at NMS->SMS Control->Password, which is an optional

parameter.
When there is a password, SMS command has following structure: Password: cmd
When there is no password, SMS command has following structure: cmd

 Cmd1, cmd2, cmd3 to cmdn, which are command identification number 0000 – 9999

5.2.2 SMS Control Steps

1. Use command Password:cmd or cmd to set new parameters.
2. After setting new parameters for M1000, and then send another SMS: 0004 to save parameters and reset the

modem, then the new parameters will take effect.

3. One command in one SMS, if you want to send another command, for example, 0004, you need to send another

SMS.

Note: E.g., 1234:0101,1
1234:0004
In this command, password is 1234, 0101 is the cmd to set device’s COM type, 1 means M1000 Pro V2 select RS485,
then save parameters and reset the modem to take effect with command 0004.
You can find out more SMS configuration examples after the SMS Comands List below.