And roxul comfortboard, Brick wall components, Cement board wall components – Roxul ComfortBatt User Manual

Page 15

Advertising
background image

15

ROXUL

®

Insulation Products For Residential Thermal Applications

Typical exterior wall claddings using ROXUL COMFORTBATT

®

and ROXUL COMFORTBOARd

IS.

Air barrier

n

Air barrier is required as per building code and

necessary for effective air tightness.

n

Can be applied on the inner side or outer side of

the insulation board and should be continuous.

Brick wall Components

(shown from outside to inside)

1

Brick

2

Air space

3

Brick ties

4

1.25" (R5) to 3" (R12) of Insulating

ROXUL COMFORTBOARd

IS sheathing

5

Exterior air/weather resistive barrier membrane

6

Sheathing

7

(2 x 6) stud wall

@

16" o.c or best practice of 24" o.c.

8

ROXUL COMFORTBATT

®

cavity insulation

9

Vapor control layer

*

10

Gypsum wall board

Cement board wall components

(shown from outside to inside)

1

Cement board

2

Fasteners

3

1 x 3 furring strips

4

1.25" (R5) to 3" (R12) of insulating

ROXUL COMFORTBOARd

IS sheathing

5

Exterior air/weather resistive barrier membrane

6

Sheathing

7

(2 x 6) stud wall

@

16" o.c or best practice of 24" o.c.

8

ROXUL COMFORTBATT

®

cavity insulation

9

Vapor control layer

*

10

Gypsum wall board

1

1

9

9

3

3

4

4

7

7

5

5

6

6

8

8

10

10

2

2

*Check with your state/municipal building code for approved vapor barrier/retarder information.