TROUBLESHOOTING (cont.)

Brew cycle will not start (cont.)

Water is not hot

PROBABLE CAUSE

REMEDY

3. ON/OFF Switch

4. Start Switch

5. Timer

6. Solenoid Valve

7. Water strainer/flow control

(.222 GPM) Early models

1. Tank Heater Switch

2. (A) Limit Thermostat

(B) Thermal Cut-Off (Brewers

with Faucet)

CAUTION - Do not eliminate

or bypass limit thermostat or

thermal cut-off. Use only BOM

replacement parts.

3. Control Thermostat

4. Tank Heater

Refer to Service - ON/OFF

Switch for testing.

Refer to Service - Start Switch

for testing procedures.

Refer to Service - Timer for test-

ing procedures.

Refer to Service - Solenoid Valve

for testing procedures.

(A) Direction of flow arrow must

be pointing towards brewer.

(B) Remove the strainer/flow

control and check for obstruc-

tions. Clear or replace.

Refer to Service - Tank Heater

Switch for testing procedures.

Refer to Service - Limit Ther-

mostat for testing procedures.

Thermal Cut-Off for testing

procedures.

Refer to Service - Control Ther-

mostat for testing procedures.

Refer to Service - Tank Heater

for testing procedures.