Salsbury Industries 3500 Series Vertical Mailboxes User Manual

Vertical mailboxes – 3500 series, Please see important instructions on back, Installation instructions

Advertising
background image

SALSBURY INDUSTRIES

1010 East 62

nd

Street, Los Angeles, CA 90001-1598

Phone: 1-800-624-5269 Int’l Phone: 323-846-6700

Fax: 1-800-624-5299 Int’l Fax: 323-846-6800

www.mailboxes.com engineering

@

mailboxes.com

Installation instructions are provided as general guidelines. It is advised that a professional installer be consulted. Salsbury Industries assumes no product assembly or installation liability.

Copyright © 2009 Salsbury Industries. All rights reserved. (Rev. 04, 9/23/09)











With their durable powder coat finish and all aluminum construction,

Salsbury’s 3500 series vertical mailboxes will provide years of

maintenance free service.

SURFACE MOUNTED

RECESSED MOUNTED

Units mount directly to a

surface and are attached
with mounting hardware
through the back.
(Hardware not included.)

Units fit into a rough

opening and are secured
with mounting hardware
through the back or side

panels of the unit.
Recessed units include a

flanged collar which fits
over the rough opening.

(Hardware not included.)



Surface unit dimensions

Recessed unit rough opening dimensions

SURFACE

Width

Height

Depth

3503 18-3/4”

19”

7-1/2”

3504

24-1/4”

19”

7-1/2”

3505 29-3/4”

19”

7-1/2”

3506

35-1/4”

19”

7-1/2”

3507

40-3/4”

19”

7-1/2”

RECESSED

1-High

2-High

3503 17-1/4”

17-3/4”

36-3/4” 7-1/2”

3504

22-3/4”

17-3/4”

36-3/4” 7-1/2”

3505 28-1/4”

17-3/4”

36-3/4” 7-1/2”

3506

33-3/4”

17-3/4”

36-3/4”

7-1/2”

3507 39-1/4”

17-3/4”

36-3/4” 7-1/2”

Vertical Mailboxes – 3500 Series

Installation Instructions

PLEASE SEE IMPORTANT INSTRUCTIONS ON BACK

These units are U.S.P.S. approved to the required

security upgrades of USPS-STD-4B+ effective March
2005.

Notes

1. No more than two tiers of mailboxes may be installed.
2. Wall opening and lumber frame must be square.

3. Mailboxes should be shielded from direct weather conditions.

4. Store keys in a safe place until ready for use.

5. Hardware is not included to fasten units into rough opening.

Installation Instructions

1. If recessed unit, create rough opening in wall per dimensions in

Rough Opening Table. Units must be securely supported by a frame
constructed of 2”x4” lumber.

2. Remove unit from carton and place in an upright position on a

table or other flat surface.

3. Remove the compartment assembly from the frame by tilting the
compartment assembly forward until it extends approximately two

inches from the frame. Then lift the compartment assembly upward

so that its base clears the hinge pins located at the bottom of the

unit. Swing the lower end of the compartment assembly outward and
remove it from the frame.

4. Mount the frame in the desired location. Caution: Do not deform,

force, or twist the frame to fit an incorrect rough opening or

irregular surface. If the frame becomes deformed, it will not retain
proper alignment with the compartment assembly. Units serviced by

the United States Postal Service must be installed with the master

lock opening a minimum of 30” and a maximum of 58” above the

finished floor.

5. Replace the compartment assembly into the frame, reversing the

procedure in step 3 above.

Security Caution

The tenant door at or near the center of the compartment array, in

addition to providing access to a tenant’s mail, also provides access

to the USPS Arrow Lock that provides access to all compartments.

For the sake of security of the entire compartment array, it is

important that this tenant door be securely locked at all times,
even if there is no tenant receiving mail via this door.

Advertising