Model 

Engine 

Power 

kVA               kW 

P.R.P(1)     S.By(2)        P.R.P(1)       S.By(2) 

Cyl

Feed

(3)

 

Dimensions mm.**

L             W           H 

Weight** 

Kg 

Fuel 

Tank Ltr 

Fuel Cons.*

L/h. 

HYW‐8 T5 

3TNV76 

7,8 

8,6 

6,2 

6,9 

3L 

NA 

1 475 

750 

1 110 

611 

23 

1,98 

HYW‐13 T5 

3TNV88 

12,3 

13,3 

9,8 

10,7 

3L 

NA 

1 475 

750 

1 110 

666 

23 

2,74 

HYW‐17 T5 

4TNV88 

16 

17 

12,8 

13,6 

4L 

NA 

1 920 

900 

1 230 

701 

38 

3,63 

HYW‐20 T5 
 

4TNV84T 

20 

22 

16 

18 

4L 

TC 

1 920 

900 

1 230 

720 

38 

4,25 

HYW‐35 T5 

4TNV98 

31 

33 

25 

27 

4L 

NA 

2 000 

950 

1 270 

905 

60 

6,56 

HYW‐45 T5 

4TNV98T 

41 

45 

33 

36 

4L 

TC 

2 250 

1 050 

1 450 

1 081 

65 

7,78 

 

*Fuel consumption measured in ltr/hr. at 75% load at 1500 rpm at 50Hz.  

**Weights and dimensions are subject to variations depending to the 
generators configuration solicited by the customer. 
To be consulted by Scan Tech. 
 
Ambient reference conditions: 
1 000 mbar, 25°C, 30 % relative humidity. Rating according to ISO 3046 
 
1 – P.R.P. Prime Power – ISO 8528: Prime power is the maximum power 
available during a variable power sequence, which may be run 
for an unlimited number of hours per year, between stated maintenance 
intervals. 
The permissible average power output during a 24 hours period shall not 
exceed 80% of the prime power. 
10% overload available for governing purposes only. 
 
2 – Standby power (ISO 3046 Fuel Stop power): Power available for use at variable loads for limited annual  

 

time (500h), within the following limits of maximum operatingtime: 100% loads 25h per year – 90% loads  
200h per year. No overload available. 
Applicable in case of failure of the main in areas of reliable electrical network. 
 
3 – NA= Natural Aspirated 
       TC= Turbocharged 
 
 

Scan Tech reserve the right of modify any characteristic without prior notice. Weights and dimensions based on products standards and sec / illustrations may include optional equipment. 
Technical data here described correspond with the available information of the moment of printing. Industrial design under patent. 

 