Schwank IEP-2024 User Manual

Page 9

Advertising
background image

9

IM110810

RD: AUGUST 2011

RL; 1A

BA

InfraSave IEP-2024 Manual

4. INSTALLATION INSTRUCTIONS

General

: READ ALL INSTRUCTIONS AND PLAN THE INSTALLATION

BEFORE PROCEEDING

This appliance conforms to ANSI/UL 2021 and is certified to CAN/CSA C22.2 No.46. This ap-

pliance is approved for outdoor and indoor non-residential use. Do not use this heater in envi-

ronments such as bathrooms and laundry rooms.
The heater must connect to a properly grounded 230 - 240Vac outlet on a copper wire electri-

cal supply circuit. Installation must conform with the latest edition Electrical Code ANSI/NFPA

N0 70 in the U.S.A. and PART 1 CSA C22.1 in Canada.
A mounting bracket is supplied with the heater, and can be mounted to a wall or post. The

heater must be mounted to this bracket during operation. Hardware to fasten the mounting

bracket to the structure is determined by site conditions, and is field supplied by the installer.

IMPORTANT:

Always maintain the minimum clearances from the floor, ceiling,

side walls, and combustible materials. Refer to Table 2 and Figure 2 next page.

Locating the Heater

:

Warning:

Use of this heater in coastal salt-air regions can result in corrosion of the aluminum

body and reflector, and premature failure the heat lamp. Corrosion and failure resulting from

use in coastal areas represents normal use in that environment and is not covered by war-

ranty.
1. The heater is designed for wall or post mounting and must be installed at least 6 feet (1.8

m) above the floor.

2. Ensure that clearances from the heater meet or exceed the minimum required clearances

in Table 2, and Figure 2 below: Above; to the Floor; to a Side wall; and to Combustible

materials.

3. The heater must be connected to a properly grounded 230 - 240Vac copper wire circuit.
4. The heater should never be placed nor mounted directly under a wall electrical outlet.
5. A minimum distance of 3 ft (36 inches) [90 cm] must be maintained between the front grille

and flammable items (e.g. curtains), walls and other structures.

6. Do not allow an electrical cord to pass in front of the heater or to touch any hot surface.
7. The appliance must not be mounted directly on flammable materials (no wood or similar).
8. Do not expose the heater to rain or other moisture.
9. Since the appliance radiates heat, no obstruction or object such as furniture should be

placed between the heater and the person being heated.

10. Do not use heater on a soft surface, like a bed, where air openings may become blocked.
11. A heater has hot surfaces and potentially arcing or sparking parts inside. Do not use in

areas where gasoline, paint, or flammable vapors or liquids are used or stored.

Advertising