SDC LR100HK-EM (Hager) EXTERNAL ELECTRIC LATCH RETRACTION DEVICE KIT User Manual

Step 2, Step 1

Advertising
background image

INSTALLATION INSTRUCTIONS LR100HK-EM (Hager)

EXTERNAL ELECTRIC LATCH RETRACTION DEVICE KIT

P:\INSTALLATION INST\SWITCH KITS\INST-LR100KK-EM.vsd REV -

07-12 Page 1

Any suggestions or comments to this instruction or

product are welcome. Please contact us through

our website or email [email protected]

Step 2

Carefully slide the assembly
back out until the linkage JUST
makes contact with the latch
retraction rod. Tighten set
screws.

ELECTRICAL DATA

24VDC @ 500/180mA

RED (+)

BLK (-)

PATENT PENDING

NOTE Retro-Fitting Vertical Rod Devices:

Before retro-fitting an electric latch assembly into a vertical device, the following must be done
to ensure proper alignment. Disconnect the vertical rods from the device. Install the electric
latch assembly as shown above. Once the ELR is properly installed energize it so that the
push pad is dogged down, by doing so it will allow for proper alignment for the vertical rods.
Finally reconnect the vertical rods to the device and make the proper adjusments.

801 Avenida Acaso, Camarillo, Ca. 93012 • (805) 494-0622 •
www.sdcsecurity.com • E-mail: [email protected]

SET

SCREWS

TIGHTEN SET

SCREWS TO

LOCK DEVICE

IN POSITION

4X SET SCREW

LR100 LINKAGE

Step 1

Slide the Electric Latch Retraction
assembly into device and attach
the linkage to the latch retraction
rod (short linkage for standard,
long linkage for 4' device).

Short

Long

Advertising