P:\INSTALLATION INST\SWITCH KITS\INST-LR100ARK-VERT.vsd REV D 08-14 Page 1

801 Avenida Acaso, Camarillo, Ca. 93012 • (805) 494-0622 •
www.sdcsecurity.com • E-mail: [email protected]

Any suggestions or comments to this instruction or

product are welcome. Please contact us through

our website or email [email protected]

ELECTRICAL DATA

24VDC @ 500/180mA

RED (+) BLK (-)

PATENT PENDING

Assemble brackets
as shown for different
size Exit Devices.

Push Bar
support bracket

Disconnect the spring-bolt latching
assembly and use it to connect the
ELR bracket assembly to the existing
components as shown.

Install the ELR bracket
assembly into device
extrusion, over the Push
Bar support brackets.

Apply power to the ELR unit to
make it draw the sliding latch
bracket back to the open position.
Secure in position by tightening the
set screws in the ELR assembly.

48"

36" or 42"

Slide ELR into back of device
and attach to bracket assembly
with supplied screw.

Remove End Cap

INSTALLATION INSTRUCTIONS LR100ARK

ADAMS RITE ELECTRIC LATCH RETRACTION DEVICE KIT

VERTICAL ROD EXIT DEVICE

MODELS: 3100, 3600, 8100, 8200, 8500 & 8600

When retrofitting to existing

vertical rod devices, adjustment

of the rods is required for proper

operation of the Electric Latch

Retractor. Once the unit is

properly installed, energize it so

the latch is dogged down, then

reconnect the vertical rods to the

device and make the proper

adjustments.