LINK
ADAPTER
2.450"
CUT EXISTING BASE TO
DIMENSION SHOWN
PLACE ADAPTER OVER
DEVICE AND USE AS A
TEMPLATE TO DRILL A
.107 DIA. THRU HOLE
TAP THE THRU HOLE FOR
6-32 THREADS AND ATTACH
THE ADAPTER WITH
SUPPLIED 3/8” TRUSS HEAD
SCREW
6-32 x 3/8"
PLACE E.L.R. LINKAGE INSIDE
ADAPTER AS SHOWN AND
SECURE IN PLACE WITH
SUPPLIED RETAINING LINK AND
4-40 x 1/4" PAN HEAD SCREW.
4-40 x 1/4”
RETAINING LINK
E.L.R. LINKAGE