801 Avenida Acaso, Camarillo, Ca. 93012
(805) 494-0622 • Fax: (805) 494-8861
www.sdcsecurity.com • E-mail: [email protected]

The E6200 Series magnetic lock is mounted to the underside of the header, on the stop side of the door.

P:\INSTALLATION INST\Electromagnetic Locks\EXCEL\INST-E6200.vsd REV -

07-10 Page 1

Any suggestions or comments to this instruction or

product are welcome. Please contact us through

our website or email [email protected]

INSTALLATION INSTRUCTIONS

E6200 SERIES MAGNETIC LOCK

Electrical Instructions:

Use properly fused U. L. Listed Power Supply

Do not install a diode in parallel with any magnetic lock. A diode
will cause a delay when releasing the door and residual magnetism
to occur.

Although SDC recommends the use of a DC power supply, a
transformer with an adjacent mounted full wave bridge rectifier
may be used. A significant drop will occur when using a full wave
bridge rectifier.

Any low voltage condition will cause erratic operation of the
optional board sensor.

When using a full wave bridge rectifier all access controls and/or
release contacts must be located between the EMlock and rectifier
to ensure quick release.

Electrical Specifications:

Dual Voltage

12 or 24VDC

Power Consumption

.250mA@12VDC
.125mA@24VDC

DS Door Status Sensor SPDT, 500mA@30VDC
LS Lock Status Sensor SPDT, 2A@30VDC

Mounting Screws

Armature

Frame

Outswing