SDC 636RF User Manual

SDC Power suppliers

Advertising
background image

P:\INSTALLATION INST\Power Supplies\INST-636RF\INST-636RF.VSD Rev F 06-06

REGULATED POWER SUPPLY

INSTALLATION INSTRUCTIONS

MODEL 636RF

SECURITY DOOR CONTROLS

3580 Willow Lane, Westlake Village, CA 91361-4921
(805) 494-0622 • Fax: (805) 494-8861
www.sdcsecurity.com • E-mail: [email protected]

MAIN SYSTEM ON-OFF

FIGURE C

Master ON/OFF

Switch (N/C)

Min. Switch

or

Contact Ratings

100mA @ 30VDC

+ _ C

POWER SUPPLY SPECIFICATIONS

Input Voltage: 115 VAC @ 60hz
Input Current: 1.8 amps Max.

Output Voltage: 12/24VDC (Regulated)
Output Current: 6 amps
Ripple Voltage: 0.05 Volts Max.

Battery Charger Max. Current: 0.35 amps
Maximum recommended battery size: 7 ah
(Replace batteries every 3 years)

Suitable Uses:
Electric Lock Power Supply
Access Control Power Supply

TEST UNIT YEARLY

12 Volt

Mode

Battery

Connections

SWITCH SET
FOR
12VDC

+

_

12VDC

+

_

SWITCH SET
FOR
24VDC

+

_

12VDC

+

_

12VDC

+

_

24 Volt

Mode

Battery

Connections

BATTERY 1

7ah

POWER

SUPPLY

BOARD

BATTERY 1

7ah

COMPONENT LOCATIONS

FIGURE B

STANDARD BOX

CONTROL
MODULE

CONTROL
MODULE

CONTROL
MODULE

CONTROL
MODULE

CLASS 2

OUTPUTS

6 AMP

OUTPUT

_

C

AUXILIARY

RELAY

CONNECTION

SYSTEM

STATUS

LED

BATTERY

+

_

BATTERY INPUT

TERMINALS

24V POSITION
12V POSITION

VOLTAGE SELECTION

NOTE: POWER MUST BE

TURNED OFF BEFORE

CHANGING VOLTAGE

AC INPUT
CIRCUIT
BREAKER

AC INPUT:
GRN – GROUND
WHT – NEUTRAL
BLK - HOT

FIGURE A

MANUAL

RESET

VOLTAGE

SELECT

12V

24V

LED STATUS LEGEND:

YELLOW – SYSTEM OK

RED – NO AC INPUT

GREEN – NO DC OUTPUT

+

2A

+

2A

+

MAIN

+

2A

Advertising