SDC 463U/463NU REQUEST-TO-EXIT SWITCH User Manual

Exit, Push to, Push to exit

Advertising
background image

Input Voltage Requirements:
12-24V AC/DC

Current Draw:
Idle-30mA, Active-150mA

Output:
1 Dry Relay Contact, SDPT
3 Amp @ 30VDC (Resistive)

Relay Time:
Adjustable – 1 to 30 seconds
or Toggle Mode – ON/OFF

Switch Operating Environment:
-40° F to +160°F (-40° C to +70°C)

Dimensions:
463U - Standard
4.75" H x 3" W x 1.125" D
(120.65 x 76.20 x 28.58 mm)
463NU - Narrow
4.75" H x 1.75" W x 1.125" D
(120.65 x 44.45 x 28.58 mm)

Specifications

INSTALLATION INSTRUCTIONS

MODEL 463U/463NU

REQUEST-TO-EXIT SWITCH

Mounting Method

463U:
Mounts directly to a single gang switchbox.

463NU: Mullion mount
(See template below. Not to scale.)

1.75"

Faceplate

4.75"

Faceplate

1.562"

1-9/16"

2.875"

2-7/8

"

#6-32 Tapped (X 2)

C

L

0.25"

¼”

Any suggestions or comments to this instruction or

product are welcome. Please contact us through

our website or email [email protected]

P:\INSTALLATION INST\Push and Key Switch\INST-463U.vsd REV A 01-14 Page 1

PUSH TO

EXIT

text

PUSH TO

EXIT

text

801 Avenida Acaso, Camarillo, Ca. 93012 • (805) 494-0622 •
www.sdcsecurity.com • E-mail: [email protected]

Advertising