SLS0033 SLS Series glare/spill Instruction-A 1/14

Drawing Number: 268-1118-9901

Target Aiming Instructions: (See Figures 1,3a,3c)
(Aiming Sight “SLSAIMINGSIGHTAXL” to be ordered separately)
1. Install aiming sight bracket

(S) in the socket housing (C) as shown in

Figure 3a. Ensure alignment to boss

(T).

2. Loosen main fixture mounting bolt

(M) add socket housing

retaining bolt

(U).

3. Look through the hole at the outermost end of the aiming sight bracket.
4. Align center of hole with the top left edge of lens door retaining latch

(V)

as shown in Figure 3b.
5. Aim the fixture by aligning the hole and the left edge of the latch with
the desired aiming location. See Figure 3c.
6. Tighten the main mounting bolt

(M) to 150 ft. lbs. and the socket

housing retaining bolt

(U) to 35-40 ft. lbs.

7. Rotate the aiming/repositioning stop bracket

(X) BACKWARDS until

the stop rest firmly against the tab on the socket housing and tighten the
retaining screw

(W). (See Figure 4).

Fast Aim Aiming Instructions:
NOTE: Target aiming is the IES preferred aiming method. Some minor

adjustments may be required as with any preset aiming system.

To position the fixture horizontally: (See Figure 1)
1. Loosen main fixture mounting bolt

(M).

2. Rotate the fixture to desired position using the horizontal aiming indicator

(Y) and the degree markings on the horizontal aiming plate (K).

3. Tighten the main mounting bolt

(M) to 150 ft. lbs.

To position the fixture vertically: (See Figure 4)
4. Loosen the screw (W) holding the vertical aiming/repositioning
stop bracket

(X).

5. Rotate the bracket to the desired position using arrow indicator

(Z) on

the ballast housing and degree markings on the bracket.
6. Tighten the bracket retaining screw

(W).

7. Loosen the socket housing retaining bolt

(U) and rotate the socket/

reflector assembly forward until it rests against the aiming
stop bracket

(X).

8. Tighten the socket housing retaining bolt

(U) to 35-40 ft. lbs.

Relamping Instructions:
1. Ensure repositioning stop

(X) is set and loosen the socket housing

retaining bolt

(U).

2. Rotate socket/reflector assembly back to gain access to
lamp compartment.
3. Release latches and swing lens door assembly open.
4. After relamping, reverse steps 2 & 3. Ensure proper seal of lens
door gasket.
5. Tighten the socket housing bolt

(U) to 35-40 ft. lbs.

SLS SERIES FLOODLIGHT GLARE AND SPILL CONTROL

INSTALLATION AND SERVICING INSTRUCTIONS

Advertising