Energy saver – Bock Water heaters Energy Saver 80PDVILN-150 User Manual

Page 2

Advertising
background image

www.bockwaterheaters.com

110 South Dickinson Street , Madison, Wisconsin 53703

Toll Free 800.794.2491

Phone 608.257.2225

Fax 608.257.5304

80029 Rev 6/08

Natural Gas use the suffix "NA", Example: 80PDVI-150-NA
LP on 80PDVI-250 and 100PDVI-250 only. Use suffix "XA" to order. Example: 80PDVI-150-XA
ASME Construction available on the 80PDVI-250 and 100PDVI-250 only; Use suffix "A" to order; Example: 80PDVI-250-NA-A
For Low NOx compliance to meet SCAQMD requirements, place an "LN" in the model number; Example: 80PDVILN-250-NA
T=Top, F=Front, R=Rear

These models meet or exceed the Thermal Efficiency and Standby Loss Requirements of ASHRAE 90.1b current standard.

115V A.C. Required

T&P Valve, Brass Drain Valve, Dielectric Fittings, Magnesium Anode Rods: Factory Installed

Pressures (all): Working Pressure, 150 psi; Tested Pressure, 300 psi

Warning: Installation should be in accordance with all national and/or local codes. In the absence of local codes, refer to NFPA 54 or ANSI Z21.10.1.

Caution: The recommended maximum hot water termperature setting for normal residential use is 120°F. Bock recommends a tempering valve or anti-scald

valve be installed and used according to the manufacturer’s directions to prevent scalding.

Energy Saver

P

ower

D

irect

V

ent

I

ndependent Vent System

Gas Water Heaters

This product is available from:

MODEL

NUMBER

STORAGE

(GAL)

RATED

INPUT

(BTU/HR)

1ST HR

DEL GAL

@ 100

° F

RISE

RECOVERY GPH

@ DEGREE RISE

DIMENSIONS (INCHES)

SHIPPING WEIGHT

A

HEIGHT

B

DIA.

C

TOP

WATER

CONN.

D

F&R

HOT

CONN.

E

F&R

COLD

CONN.

F

GAS

CONN.

G

TOP

VENT

HEIGHT

WATER

CONN.

GAS

CONN.

DIA.

RELIEF

VALVE

OPEN.

STD

(LBS)

ASME

(LBS)

40

° F 100° F 140° F

80PDVI-150

80

150,000

204

364

145

104

63-1/2

28-1/4

65-1/8

51-5/16 20-3/16 17-1/4

68-3/16

1-1/12(T&F)

2(R)

3/4

3/4

645

N/A

80PDVI-200

80

199,999

253

485

194

139

63-1/2

28-1/4

65-1/8

51-5/16 20-3/16 17-1/4

68-3/16

1-1/12(T&F)

2(R)

3/4

3/4

645

N/A

80PDVI-250

83

250,000

301

606

242

173

63-1/2

28-1/4

65-1/8

51-5/16 20-3/16 17-1/4

73-1/16

1-1/12(T&F)

2(R)

3/4

1

645

720

100PDVI-150

100

150,000

219

364

145

104

74-1/8

28-1/4

74-1/8

60-5/16 20-11/16 17-1/4

77-3/16

1-1/12(T&F)

2(R)

3/4

3/4

735

N/A

100PDVI-200

100

199,999

266

485

194

139

74-1/8

28-1/4

74-1/8

60-5/16 20-11/16 17-1/4

77-3/16

1-1/12(T&F)

2(R)

3/4

3/4

735

N/A

100-PDVI-250

100

250,000

312

606

242

173

74-1/8

28-1/4

74-1/8

60-5/16 20-11/16 17-1/4

82-1/16

1-1/12(T&F)

2(R)

3/4

1

735

815

Propane Gas Inputs (LP)

1ST HR.

DEL GAL.

@ 100° F

RISE

RECOVERY GPH @

DEGREE RISE

40° F

100° F

140° F

80PDVI-250-XA 225,000 BTUH

274

545

218

156

100PDVI-250-XA 225,000 BTUH

288

545

218

156

(LN) LowNOx Burners

1ST HR.

DEL GAL.

@ 100° F

RISE

RECOVERY GPH @

DEGREE RISE

40° F

100° F

140° F

80PDVILN-150

150,000 BTUH

201

364

145

104

80PDVILN-200

180,000 BTUH

250

436

175

125

80PDVILN-250

220,000 BTUH

298

533

213

152

100PDVILN-150 150,000 BTUH

215

364

145

104

100PDVILN-200 180,000 BTUH

245

436

175

125

100PDVILN-250 220,000 BTUH

283

533

213

152

A

C

G

D

E

B

F