SVC/SHC Series

Sanitary Check Valves

The patented SVC/SHC Series are vertical and hori-

zontal check valves designed specifically for use in

biopharmaceutical and parenteral drug manufacturing

applications. They are the first check valves to follow

the valve design guidelines of ASME BPE 2009.

Since no spring, hinge, mechanical return mecha-

nism or stem is used, they are crevice free, have no

areas for particle entrapment, minimize particulate

shedding, and are CIP and SIP capable, and auto-

clavable.

The SVC with Teflon, PEEK and 316/EPDM discs

are for vertical up flow installations. The NEW SVC

with floating Polypropylene disc was specifically

designed for vertical downflow process outflow and

drain installations, and is another Steriflow industry

first. The SHC is designed with any disc for hori-

zontal line installations.

How it Works:
As soon as inlet pressure exceeds the weight of

the disc plus the outlet pressure, the disc will lift.

Process media flows under the seat and through

the disc perimeter holes to the outlet side of the

valve. As flow begins to reverse, the differential

pressure across the valve drops and the disc re-

turns to the seat, closing the valve.

F

eatures

• NEW - The first and only vertical down flow

sanitary check valve that is continuously self

draining

• Applicable for gas or liquids, and suitable for

CIP and SIP, and are autoclavable

• Elimination of springs or hinges speeds open-

ing time and eliminates particle entrapment

areas

• High flow rates with minimal pressure loss com-

pared with mechanical return check valves

• Low particle shedding properties compared with

sliding disc type or spring return check valves

• Unique design eliminates dead space and crev-

ices associated with spring check valves

• All wetted internal surfaces are mechanically

polished and electropolished to SF5,

20 Ra µin (.5 Ra µm), all external surfaces are

40 Ra µin (1 Ra µm),electropolished, other

finishes optional

• Sanitary tube weld ends and Tri-clamp ends

available

• Positive shutoff without the use of a spring

a

pplications

• NEW - SVC for vertical down process outflow

and drain lines

• WFI, USP PW: Pump outlet back flow preven-

tion, POU back flow prevention

• Condensate drainage from clean steam distri-

bution loops

• Condensate drainage from process systems

using clean steam – fermenters, bioreactors,

SIP systems and sterilizers

• Sampling systems in WFI and clean water

supply systems

• Air pressure supply systems and pressure

rinse systems in pharmaceutical piping

• To replace actuated diaphragm valves on

some liquid mixing lines

• Gas (O

2

, N

2

, CDA) sparge, purge or blanket

applications

• Vacuum breaker (with filter) on vent line for

vessels or equipment

NEW - SVC for vertical

down process outflow and

drain installations

Patent, and Govt Registrations: Patents: US PAT 6,823,893; EU Pat 1319878; Canada: CRN 13987.5