Steriflow Mark 93JR Series User Manual

Mark 93jr series, Sanitary steam traps, Sanitar y v alv es mark 93jr sanitar y steam traps

Advertising
background image

Mark 93JR Series

Sanitary Steam Traps

Steriflow Valve, a Division of Jordan Valve

3170 Wasson Road • Cincinnati, Ohio 45209

Telephone 513.533.5600 • Fax 513.871.0105

Toll-Free Telephone 800.543.7311

[email protected] • www.steriflowvalve.com

Sanitar

y V

alv
es Mark

93JR

Sanitar

y Steam

Traps

The Mark 93JR is an ultra compact, balanced port,
thermostatic steam trap designed specifically for use in
validated clean steam systems for low to medium con-
densate flows. The sanitary design follows ASME BPE
guidelines including a 20Ra

µin internal finish, self-

draining design, and all relevant materials, marking

and documentation.

The MK93JR has been specifically designed to provide
low to medium flow rates at low subcooling levels. In
lab testing, the MK93JR consistently exhibited excel-
lent flow rates at subcooling levels of less than 3°F or
less (<1,7°C). Note: Low subcooling operation insures
that condensate is less likely to back up and wet (cool)
the upstream validated temperature sensor.

How They Work

During start-up, the bellows element is contracted and
fully open to discharge all non-condensable gas and
condensate. The heat of entering steam causes the
element to expand, closing the valve. As condensate
accumulates in the body, the element cools, causing
the bellows/stem tip to retract allowing condensate to
drain.

Features

Compact design, small lay-in length - ideal for
compact installations like process skids

The only compact sanitary trap with a Tri-clamp
body to facilitate quick bellows assembly
change out

Low subcooling operation reduces probability
of temperature validation faults and resultant SIP
delays

All 316L stainless steel housing and internals

Polished components – body interior is mechani-
cally polished to ASME BPE SF1, 20 μin (0,5 Ra μm)
mechanical polish. External body is mechanically
polished to 40 Ra μin (1 Ra μm).

Sanitary clamp ends standard, other ends (tube
weld, threaded, ISO/DIN) available upon request

Self draining when installed vertically (outlet side
down)

FDA and USP Class VI TFE-VIT gasket standard

Option for electropolished body

Standard Steriflow Valve warranty applies

Applications

Typical application is for SIP clean conden-
sate drainage on validated bioprocess skid
systems. In this environment, the compact
size makes it ideal for:
- Fermenters, Bioreactors, Separation,
Filtration and Purification skids and
formulation and filling equipment
- May also be used for clean steam
distribution line drainage

Advertising