Step #2


Check the Electrical Supply Requirements

This product must be installed in accordance with national, state and local
electric codes. The following table provides the correct voltage, amperage
and frequency that must be supplied to the cooktop.

SUMMIT

Model #

Maximum

Connected

Load

Required

Power Supply

Input

Minimum

Wire Size

CR 1115

1200 Watts

120V

AC/10A/60Hz

#16 AWG

CR 2110

2400 Watts

120V

AC/20A/60Hz

#16 AWG

CR 2220

2400 Watts

220V

AC/10A/60Hz

#16 AWG

CR 3240

3600 Watts

220V

AC/15A/60Hz

#16 AWG

The supply must be from an individual grounded circuit that is protected by
a circuit breaker and rated per the specifications for the various models as
shown in the table above.













WARNING: INSTALLATIONS MUST COMPLY WITH ALL LOCAL,
STATE AND NATIONAL ELECTRICAL CODES.

Failure to comply with the applicable codes may result in fire,
property damage, personal injury or death.

If the electric power supply does not meet the product
specifications, consult with a licensed electrician before
proceeding with installation.