b)

Disconnect the connection to the Standing

Pilot Switch as shown in Figure 14.
c) Disconnect the TH wires from under the valve
and plug in the two (2) orange wires as shown
in Figure 15.
d) Disconnect the 3/16” connector from the valve
and connect the two (2) blue wires as shown in
Figure 16.
17. Plug the power cord from the PVK Control Box
into the top outlet of the Electric Box on the side
of the unit as shown in Figure 17.
18. Reinstall the Side Access Cover and continue
with the appliance

Figure 14

:

Disconnecting Standing Pilot

Switch.

Figure 15

:

Disconnecting TH Wire & Connecting

Orange Wires.

Figure 16

:

Changing Valve Wiring.

Installation steps as shown in the Instruc-
tion Manual.
When installed, the Power Vent Kit, must
be electrically grounded in accordance
with local codes or, in the absence of local
codes, with the National Electrical Code,
ANSI/NFPA 70, or the Canadian Electrical
Code, CSA C22.1.

WARNING: Electrical Grounding Instructions

This appliance is equipped with a three-prong (grounding) plug for your protection against shock
hazard and should be plugged directly into a properly grounded three-prong receptacle. Do not cut
or remove the grounding prong from this plug.
Periodic examination of venting systems should be done by a qualified agency.

Figure 17

:

Plugging PVK into Electric Box.

16. When using the 50-1970 Power Vent Kit, there is no need to have the unit set to continuous pilot, connect the 9V clip of the PVK to the 9V clip of the
unit.
a) Remove the Access Cover from inside the firebox by removing all ten (10) T-20 screws (see Figure 13).