Care and cleaning, Troubleshooting – Black & Decker GSR10 User Manual

Page 5

Advertising
background image

8

7

4. Plug in the unit into an electrical outlet.
5. Press the On/Off (I/0) switch (S).
6. Remove the steam nozzle from its holder facing upward, away

from you and press the Steam button (T). The indicator lights
on the unit illuminate and in a few seconds steam is released.

Important:
• Never place your hand in front of steam nozzle where steam

is being released.

• Do not leave the steam nozzle in one area for a long period of

time because the garment will get wet.

7. Use the lint brush to remove lint from the fabric as it steams.
Automatic Shutoff
The unit shuts off automatically:
• After 30 minutes of inactivity
• If water tank is empty
To use the unit again, turn Off then On and resume operation.

Care and Cleaning

This product contains no user serviceable parts. Refer service to qualified service
personnel.
Cleaning
1. Make sure the unit is off.
2. Wait for the unit to cool down completely before draining the water tank.
3. Remove water tank and drain any remaining water.
4. Wipe the outside surface with a damp cloth. Never immerse the unit in water

or other liquids.

Storage
• Make sure unit is off and unplugged.
• Unit stores vertically for compact storage. If you need more height, you can

adjust the extension tubes.

• Insert the steam nozzle in its holder and wrap the cord around the cord wrap.
Important: If you want to leave your unit ready for daily use, just leave the water
tank filled and in place.

S

T

PROBLEM

CAUSE

SOLUTION

Steamer Does

1. Steamer is not plugged

1. Plug power cord into

Not Get Hot

into electrical outlet.

electrical outlet.

2. Flexible hose is not

2. Check flexible hose

connected properly.

connection.

3. Unit shuts off

3. Turn off unit then

automatically.

on again.

No Steam

Water level is too low.

Refill the water tank
following instructions
on page 6

Water Drips

Condensation has formed

Hold the steamer hose

From The

inside the steamer hose.

upright fully extended and

Steam Nozzle

allow excess moisture to
drain back in the water
reservoir.

TROUBLESHOOTING

GSR10Pub1000002369 6/14/05 4:57 PM Page 8

Advertising