40

FLUID COOLING | Mobile MF Series

A

IR C
O

O

L

E

D

MF

Features

n

Same as M Series with DC Fan or

Hydraulic Motor

n

3/8” Tube Size

n

Aluminum Fins

n

Low AMP Draw 12 or 24 Volt DC Motor

n

Heavy Duty Construction

n

Optional Serviceable Relief

Bypass Valve

n

Optional Fan Control Switch

n

Long Life Hydraulic Motors

n

Heat Removal TO 50,000 BTU/Hr.

n

Oil Flows to 150 GPM

n

Mounting Brackets Included

n

SAE, NPT or 37° Flare Oil Connections

n

Rugged Steel Manifolds

Materials

Tubes Copper
Fins Aluminum
Turbulators Steel
Manifolds Steel
Fan Assembly High Impact Plastic
Motor Displacement .22in

3

/Rev. (Hydraulic)

Maximum Pressure 2000 PSI (Hydraulic)
Allowable Backpressure 1000 PSI (Hydraulic)

Relief Bypass Valve Option

MODEL DESCRiPTiON
MFR-15 3/4”, external, all steel valve.

Available in either 30 PSI or 60 PSI

settings. May be removed for

servicing.

MFR-30 1-1/2”, external, all steel valve.

MFR-60 Available in either 30 PSI or 60 PSI

settings. May be removed for

servicing.

Ratings

Operating Pressure 300 psi
Operating Temperature 350° F

DC current required

Hydraulic Motor Data

Number

Oil Flow Required

Minimum Operating

Maximum Fan Speed

of Fans

12 Volt

24 Volt

(GPM)

Pressure (PSi)

(RPM)

1

12.5 amps

6.3 amps

2.1

300

2200

2

25 amps

12.6 amps

4.2

300

2200

Motor

Specification

NM

- No Motor

4A

- 12 Volt DC

4B

- 24 Volt DC

9

- Hydraulic Motor

*Other connection types available. Please consult factory for assistance.

How to Order

Model

Series

MF

MFR

- Relief

Bypass

Included

Model Size Selected

Connection

Type*

1

- NPT

2

- SAE

3

- BSPP

7

- 37° Male Flare

Relief Bypass

Blank

- No Bypass

30

- 30 psi

60

- 60 psi

ADD FOR

MFR

MODELS ONLY