3 operation, 1 input led, 2 bat 1 and bat 2 leds – Ultralife MRC-135A User Manual

Page 7: Operation, Onnections and, Tart, Up for, Ower, Nput, Ontrols and

Advertising
background image

MRC-135A Operation Manual

Newark, New York | 315-332-7100 | Fax: 315-331-7800

©2012 Ultralife Corporation • www.ultralifecorp.com • All information is subject to change without notice.

The information contained herein is for reference only and does not constitute a warranty of performance. •

19 DEC 2012

Rev: C

3 OPERATION

The subsequent sections will list in chronological order how to operate the battery

charger safely and efficiently.

3.1 Connections and Start-up for Power Input

For start-up connections, follow the directions below:

1. To charge the battery, first connect the MRC-135A to a battery via the

connector on the bottom of the unit.

2. Connect the MRC-135A to a 50 or 60 Watt solar panel using a MRC135-07-01

solar cable.

NOTE: For DC power source, use the PCP-253 DC power cable.

3. Wait 4.5 to 8 hours for the battery to fully charge.

3.2 Controls and Indicators (LEDs)

The MRC-135A has three light emitting diodes (LEDs) located beside the input

connector, described in the two following sections.

3.2.1 Input LED

The Input LED indicates the recognition of a power source. When the led is on the

MRC-135A is receiving power.

3.2.2 Bat 1 and Bat 2 LEDs

The “Bat 1” LED indicates the status of the first battery section. “Bat 2” indicates the

status of the second battery section. There are three status indicators for these LEDs,

as follows:

u

When the LED lights are on, the battery is charging.

u

When the indicators are off, the battery is charged.

u

When the LED is blinking, the battery has a fault.