5 MAINTENANCE

Maintenance for this product is described in the following sections.

5.1 Cleaning Charger Air Filter

Remove Air Filters by unscrewing captive thumb screws. Spray off filter with air or water
and thoroughly dry filter. Re-attach filter(s) to assembly.

Extreme Dust: If excessively dusty conditions are encountered the unit will shut down
due to and air flow restriction. In this situation:

 Remove the filters from the Charger Box and blow out from the back side.

 Power up charger box so fans are active.

 Gently blow off equipment and power supply from the front of the box without

extending into the Charger Box.

 Re-attach cleaned filters to charger box and use.

Note: Do not add any additional filtering. It may prevent the unit from operating
correctly.

5.2 Cleaning Units

If the unit requires cleaning, it is suggested to use a mild cleaner and water solution and
to wipe with a damp cloth. Do not submerge unit in cleaning solution. If connectors
require cleaning on the Battery Box, charger, or batteries, use a contact cleaner
designed for electronics interfaces such as CAIG DEOXIT or PROGOLD.
www.caig.com

5.3 Firmware Upgrade

If firmware for the Battery Box requires updates, there is a manufacture access panel to
a USB port on the side of the unit. If a Firmware upgrade is required contact Ultralife
Corp.

5.4 Battery Conditioning

Under normal use the batteries should not require conditioning. If the Battery Box is
used to partial depth of discharge frequently, performing a full discharge followed by full
charge will re-calibrate and condition the battery.