2 PRODUCT DESCRIPTION

The CH0004 Battery Charger/Conditioner is designed to provide a safe and effective recharge of the
following batteries:

BB-390/U / MAI-390 Nickel Metal Hydride

BB-590/U / MAI-590 Nickel Cadmium

BB-2590/U Lithium-ion

UBI-2590 Lithium-ion

UBBL09 Lithium-ion

These batteries are rechargeable batteries commonly used with Tactical Communication Equipment.
Each battery has the same form factor and in many cases is interchangeable for battery operated
equipment. The CH0004 will charge up to two batteries at one time. Additionally, the user can
charge multiple battery types at the same time.


CAUTION:

Prior to using the CH0004, please read the safety and caution

instructions located in section 1 to prevent the mischarge or catastrophic
destruction of a battery.

While inherently safe, if the CH0004 is used incorrectly, an accident can
occur. Misuse of the CH0004 may result in damage to the battery and/or
the CH0004 battery charger.

2.1 Features

CH0004 features are described in the following subsections.

2.1.1 Charge Detection

The CH0004 automatically detects battery problems such as open cells or other battery problems,
which prevent a safe and efficient charge. There are a number of internal safeguards built into the
unit. Temperature, voltage and time are monitored throughout the fast charge. Fast charge is
terminated when the unit detects the battery has been fully charged. The CH0004 also automatically
detects different battery chemistries by the contacts or lack of contacts on the battery itself.

2.1.2 Lithium Ion Battery Detection

The charger detects the BB-2590 Li-Ion battery through the contact on the battery. When it is
detected, the charger will charge using a constant current of 1.0A until the voltage reaches 16.4V.
When the voltage is reached, the charger will go into a constant voltage mode. When the charge
current falls below 140mA, the charge is complete. There is a 12-hour safety timer if the charge
current never goes low enough. This will terminate the charge.

2.1.3 NiCad OR NiMH Battery Detection

With the lack of a contact, as with Lithium Ion batteries, the CH0004 will assume that the battery is a
Nickel-based chemistry (NiCad or NiMH). The charger will charge at a constant current of 1A while
sampling change in voltage. When a negative change in voltage is detected, the peak has been
found and the charge is complete. There is a 6 hour safety timer that will terminate the charge if the
battery never peaks. On the NiMH battery are thermistor contacts for each section that detect the
battery’s temperature.