B101278-6-0610

Operating Instructions

Before each use, inspect all hoses. If it is evident there is

excessive abrasion or wear, or the hose is cut, it must be

replaced prior to using your Broilmaster grill. Call your local

Broilmaster dealer for a replacement.

Using the Ignitor
Caution: If a burner fails to light after 5 seconds, turn the

burner OFF for 5 minutes, to allow the gas to clear, then try

again.
Note: Each burner must be lit individually.
1. Turn knob on the grill CLOCKWISE to the OFF position.

2. Turn ON gas at the source.

3. With the grill lid open, push and turn the burner control knob

COUNTERCLOCKWISE to Hi.

4. Push and hold the ignitor button until the burner lights (ap-

proximately 5 seconds).

5. If a burner does not light, turn OFF all gas and refer to the

Troubleshooting section of this manual.

6. Repeat steps 3 through 5 for other burner.

Using Matches to Light the Grill

Caution: If a burner fails to light after 5 seconds, turn the

burner OFF for 5 minutes, to allow the gas to clear, then try

again.
Note: Each burner must be lit individually.
1. Turn knob on the grill CLOCKWISE to the OFF position.

2. Turn ON gas at the source.

3. Open the grill lid.

4. For Blue Flame grills, insert a burning long wooden match

through the lighter hole on the left side of the grill. For Infra-

red grills, insert the lighting stick with a long wooden match

attached through the cooking grid to ignite the infrared burner

from the top. See Figure 19.

5. Turn the burner control knob COUNTERCLOCKWISE to

HI.

6. If a burner does not light, turn OFF all gas and refer to the

Troubleshooting section of this manual.

7. Repeat steps 3 through 6 for other burner.

Checking for Gas Leaks

Check for gas leaks every time you connect your Broilmaster

pro-

pane gas grill to a Propane gas cylinder, when a connected cylinder

has not been used recently, or when either a natural or propane grill

is being used for the first time.
Caution: Do not use an open flame when checking for leaks.

Checking for leaks with an open flame may lead to a fire or

explosion, resulting in property damage or personal injury.
To check for gas leaks:
1. Use dish washing liquid and a little water to make a soapy

solution.

2. Turn OFF the knob on the control panel.

3. Turn ON the gas at the supply or cylinder. A hissing sound

indicates a leak. Turn OFF the gas and repair the leak.

4. Apply the soapy water solution to all gas connections.

5. Look for bubbles. Bubbles indicate a leak.

6. If there are bubbles turn OFF the gas and repair the leak.

7. Turn the gas back ON and repeat the above procedures until

all leaks are repaired.

Air Shutter Adjustment For R3B

Series Only

The burner (venturi) tube air shutter is preset at the factory so that

after five minutes the burner flames are blue with well defined

cones. If, after five minutes the flame is yellow, or there is a gap

between the burner and the flame, adjust the burner (venturi) tube

air shutter as follows:
1. Turn gas OFF and let the burner cool.

2. Beneath the control panel you can access the air shutter(s)

which are located on the end of the burner tubes.

3. Loosen shutter set screw

4. Close the air shutter to the minimum opening.

5. Light the burner, wait five minutes and then carefully open the

air shutter until the flame is blue and well defined.

6. Retighten the set screw.

Figure 19

o

PeraTion

- P

roPane

& n

aTural

g

as

g

rills

LIGHTING STICK

R734

KEEP HAND AWAY FROM

TOP OF GRILL WHEN LIGHTING

INFRARED BURNER

MATCH LIGHT HOLE

BLUE FLAME BURNER

Advertising