UKT0011 Instructional Reference Datasheet

Newark, New York | 315-332-7100 | Fax: 315-331-7800

©2010 Ultralife Corporation • www.ultralifecorp.com • All specific subject to change without notice

The information contained herein is for reference only and does not constitute a warrant of performance •

30 SEP 10 UBI-05190 Rev: C

Page 3 of 4


SAFETY

 Use only approved batteries in battery box.
 Do load equal numbers of batteries in each bank in battery box.
 Use only approved cables with the battery box and charger system.
 Do not use cables that are frayed or damaged in any way.
 Do not use batteries that appear damaged in any way
 Do not stand on the battery box or charger as injury may occur
 Be sure to follow proper lifting precautions since the battery box is greater than

50 lbs.



TROUBLESHOOTING

 There is no State of Charge Display on the Battery Box:

1. Check the power switch to assure the unit is on.

2. Confirm batteries are charged above 0% and/or shore power is applied

 State of Charge is Displaying Low State of Charge:

1. Confirm equal numbers of batteries are installed in each bank.

2. Confirm UBBL10 batteries are installed in all positions in the Box.

3. Confirm battery and pogo pin contacts are clean from debris.

 Batteries do not charge:

1. Make sure temperature is below 50°C.

2. Cable not connected.

 Fully loaded Battery Box will not reach 99% State of Charge:

1. One or more low capacity batteries installed.

2. Discharge Battery Box complete and recharge.

3. If problem continues contact supplier.