SAFETY FIRST!
Follow good safety practices.
Read material safety data
sheets and related literature on
products before specification
and/or installation.

Application

During and after application, and at all times until building is occupied, maintain min. air, water, mix, and surface
temperatures of 55 °F (13 °C), and provide adequate ventilation for texture to dry properly. Inadequate ventilation
can cause objectionable board deflection and reduced texture bond/surface hardness. Do not use unvented gas
or oil heaters.

Correct equipment settings and mix consistency will maximize coverage (in ft.

2

/lb.), yet reduce aggregate fallout

(bounce-back) and holidays (board voids). A steady, high-pitched sound should be heard from the pole gun
during spray application. Slight adjustments for type and grade of aggregate in the texture may be necessary.
Adjust air spike, orifice, and air pressure to optimize atomization and width of spray fan. As the pole gun orifice
wears, it will slowly increase in size—periodically check and adjust it as necessary.

Spray texture mix on dry surface at a maximum rate of 8-10 ft.

2

/lb. For heavily textured appearance, apply

two coats of texture, letting the first coat dry thoroughly before applying the next. (Do not vary coverage rate:
check-cracking can result from excessive coating thickness, and poor hide from too thin a coating.)

Trademarks
The following trademarks used
herein are owned by United
States Gypsum or a related
company: C

OVER

C

OAT

, D

URABOND

,

E

ASY

S

AND

, S

HEETROCK

Note
Products described here may
not be available in all geo-
graphic markets. Consult your
U.S. Gypsum Company sales
office or representative for infor-
mation.

Notice
We shall not be liable for inci-
dental or consequential dam-
ages, directly or indirectly sus-
tained, nor for any loss caused
by application of these goods
not in accordance with current
printed instructions or for other
than their intended use. Our lia-
bility is expressly limited to
replacement of defective goods.
Any claim shall be deemed
waived unless made in writing
to us within thirty (30) days from
the date it was or reasonably
should have been discovered.

Manufactured by
United States Gypsum Company
125 South Franklin Street
Chicago, IL 60606

800 USG.4YOU (874-4968)
www.usg.com

J1816/2-04
©2004, United States Gypsum Company
Printed in U.S.A.

Page 2 of 2

Advertising