MODELS

ILB9

!!!!! ILB11

MOUNTING USING HANGER KIT (included)

Blower factory-shipped in straight-through

discharge position.

TYPICAL INSTALLATION

DUCTING

(Horizontal blower discharge)

Two ways to connect ductwork to a factory-shipped unit.

ROOF CAP

10” ROUND

ELBOW

10”

ROUND

DUCT

WALL

CAP

8” X 12”

TO

10” ROUND

TRANSITIONS

10”

ROUND

DUCT

ACCESS

PANEL

ACCESS

PANEL SCREW

GRILLE NUT

(Install into

square holes in

housing)

MOUNTING

BRACKET

10” ROUND

DUCT

(OUTLET)

8” X 12” TO

10” ROUND

TRANSITIONS

10” ROUND

DUCT (INTAKE)

HANGER

KIT NUT &

WASHER

HANGER

KIT BOLT

& WASHER

HANGER

KIT CHAIN

HANGER KIT

EYE-BOLT

TYPICAL INSTALLATION

MOUNTING (New Frame Construction)

CEILING

JOIST

(24”

centers
shown)

10” ROUND

DUCT

(OUTLET)

ACCESS

PANEL

Factory-shipped unit installed in new construction.

MOUNTING

SCREWS

ACCESS

PANEL SCREW

Ventilator factory-shipped

in straight-through

discharge position.

MOUNTING
BRACKETS

MOUNTING (Existing Frame Construction)

Factory-shipped unit installed in existing construction.

ACCESS

PANEL

SCREW

8” X 12” TO 10” ROUND

TRANSITIONS

10” ROUND DUCT

(OUTLET)

Ventilator

factory-shipped

in straight-through

discharge position.

MOUNTING
BRACKETS

8” X 12” TO

10” ROUND

TRANSITIONS

CEILING

JOIST

(24” centers

shown)

ACCESS PANEL

10” ROUND

DUCT

(INTAKE)

10” ROUND

DUCT (INTAKE)

GRILLE NUT

(Install into square

holes in housing)

GRILLE NUT

(Install into

square

holes in

housing)

IMPORTANT: Remove shipping tape from damper

Remove the shipping tape from the damper flap and make sure
that damper flap opens and closes freely inside the ductwork. Use
duct tape to make ductwork connections secure and air-tight.