UVP Benchtop Curing System User Manual

Page 4

Advertising
background image

BC-300 Benchtop UV Curing System

3

Part Numbers

Model

Part Number

Watts

Volts

BC-300

95-0194-01

300

120V/60Hz

BC-300

95-0194-02

300

220V/50Hz (CE Certified)

BC-300

95-0194-03

400

220V/50Hz (CE Certified)

GENERAL INSTRUCTIONS

1. After unpacking, check all electrical connections and mounting hardware to insure there is no damage.

2. If all items appear satisfactory, install ultraviolet lamp (see Lamp Installation Instructions sheets page 4).

3. to install the drop off plate on each of the curing system, refer to the “Installation of Drop Off Plate” under

Diagrams (see sheet 1979-13).

3. A) Main power and lamp on switch to OFF position. B) High/low lamp intensity (1/2) switch to high

position. C) 300 WPI systems - switch to 300 WPI setting. D) Variable speed control knob to ZERO.

4. Plug input cord into Grounded, 120 Volt 60 Hertz, 10 Amps A.C. Outlet. Do not remove ground contact

from power cord under any circumstances.

5. Switch Main Power switch to on position. This switch sends power to the lamp switch variable speed

control and activates center lamp cooling fan.

CAUTION: When fixture is operating, ultraviolet rays are emitted which are harmful to eyes and skin. Great

care should be taken to insure personnel are not exposed to direct or reflected radiation. Suitable eye protec-

tion, such as UVP UV Blocking Spectacles or Goggles should be employed when lamp is in operation.

6. When shielding is in place and/or operators are utilizing ultraviolet absorbing safety glasses, the lamp

switch may be turned on. This will light the ultraviolet lamp. The lamp requires a 3-4 minute warm-up prior

to curing applications.

7. Start conveyor belt moving. Belt should always be moving when lamp is on.

8. High/Low lamp intensity option may be utilized to operate lamp at idle mode when curing application are

on hold. Lamp will operate at approximately 1/2 the rated output and rapidly return to full power. On tri-

power models switch lamp to 125 WPI when curing applications are on hold.

9. Shut-Down Procedure:

A. High/Low lamp intensity switch to high position.

B. Tri-Power models intensity switch to 300 WPI.

C. Lamp switch to off position.

D. Reduce belt speed.

E. Allow main switch to operate cooling fan for 3-5 minutes before total shutdown. This will allow lamp

to cool evenly and will prolong lamp life.

F. Main power switch to off position.

Advertising