6

7

CLEANING AND SANITIZING INSTRUCTIONS

THE CONTAINER MUST BE CLEANED AND DRIED AFTER EACH

USE OF THE BLENDER ACCORDING TO THE FOLLOWING

INSTRUCTIONS. FAILURE TO DO SO MAY ALLOW RESIDUES OF

PROCESSED MATERIAL TO COLLECT ON THE INTERNAL SEALS

OF THE BLADE ASSEMBLY, RENDERING THEM INEFFECTIVE.
• Wash, rinse, sanitize and dry container prior to initial use and

whenever it will not be used again within a period of 1 hour.

• Wash and rinse container after each use.
• Clean and sanitize motor base prior to initial use and after

each use.

• Washing solutions based on non-sudsing detergents and

chlorine-based sanitizing solutions having a minimum chlorine

concentration of 100 PPM are recommended.

The following washing, rinsing, and sanitizing solutions, or their

equivalents, may be used.

SOLUTION

PRODUCT

DILUTION IN WATER TEMPERATURE

Washing

Diversy Wyandotte

4 Tablespoons

Hot 115˚F ( 46˚C )

*Diversol® BX/a or CX/A

/Gallon

Rinsing

Plain Water

Warm 95˚F (35˚C)

Sanitizing

**Clorox®

1 Tablespoon/Gallon

Cold 50-70˚F

Institutional Bleach

( 10-21˚C)

*Diversol

®

is a registered trademark owned by the Diversey Wyandotte Corp.

**Clorox

®

is a registered trademark owned by the Clorox Company.

• In repetitive batch-processing applications, frequent cleaning

of the container will prolong the life of the blade assembly.

In no case should actual running time between cleanings

exceed ½ hour.

• Do not use container to store processed foods or beverages.

To wash and rinse container:

1. REMOVE CONTAINER FROM MOTOR BASE. Remove lid.

Rinse container interior and lid under running water. Add

washing solution to container. Scrub and flush out the

container interior and lid to dislodge and remove as much

food residue as possible. Empty container.

IMPORTANT

NOTE: IN ORDER TO MINIMIZE POSSIBILITY OF SCALDING,

TEMPERATURE OF WASHING SOLUTION AND RINSE WATER

MUST NOT EXCEED 115˚F (46˚C), AND QUANTITY USED MUST

NOT EXCEED ¼-CONTAINER FULL.
IF HIGHER TEMPERATURES OR LARGER QUANTITIES ARE

USED, OBSERVE ALL PRECAUTIONS GIVEN IN THE OPERATING

MANUAL UNDER “HOT BLENDING INSTRUCTIONS.”
To sanitize and dry container:
1. Wipe down exterior of container with a soft cloth or sponge

dampened with sanitizing solution.

2. Fill container with sanitizing solution, cover, place on motor

base, and run on high speed for two (2) minutes. Empty

container. Dislodge any residual moisture from blade assembly

by placing empty container on motor base and running on high

speed for two (2) seconds.

3. Sanitize lid and lid insert by immersing in sanitizing solution for

two (2) minutes.

4. Do not rinse container, lid, or lid insert after sanitizing is

completed. Allow parts to air-dry.

To clean and sanitize motor base:
1. UNPLUG POWER CORD. Wipe down exterior surfaces of

motor base with soft cloths or sponges dampened with

washing solution, rinse water, and sanitizing solution. Prevent

liquid from running into motor base by wringing all excess

moisture from cloths or sponges before using them.

DO NOT IMMERSE MOTOR BASE IN WASHING SOLUTION, RINSE

WATER OR SANITIZING SOLUTION.
2. Allow motor base to air-dry before using.
Any other servicing should be performed by an authorized service

representative.

2. Wipe down exterior of container with a soft cloth or sponge

dampened with washing solution. Wash lid and lid insert in

fresh washing solution. Fill container ¼ full with fresh washing

solution, cover (with lid only but without center piece), place on

motor base and run on HI for two (2) minutes. Empty container.

3. Repeat step (2) using clean rinse water in place of washing

solution.