Scp-120 manual_10272_7 – WarmlyYours SCP-120 User Manual

Page 7

Advertising
background image

Control

Supply

Load

Contact type
Maximum Ratings

Heater hold-on timer
System test

Snow/Ice Sensors

Sensor type
Circuit type
Lead length

High Limit Sensor
Adjustment range
Dead band
Sensor type
Circuit type
Lead type

Energy Management Computer
(EMC) Interface

Inputs

Outputs

Environmental

Operating temperature
Storage temperature

SCP-120: ETI PN 22470: 120 VAC, 50/60 Hz, 35 VA
SCP-120: ETI PN 22470: 120 VAC, 24 amp max. in-
ductive
ETI PN 22471: 208-240 VAC, 24 amp max. inductive

SCP-120: Form C
SCP-120: Voltage: 120VAC
Current: 24 amps
0 to 10 hours; actuated by snow stopping or toggle switch
Switch toggles the heater contact on and off. If temperature
exceeds high limit, heater cycles to prevent damage.

Up to 6 sensors from the AIR-SS product family
NEC Class 2
Up to 500’ (152m) using 18 AWG 2-wire jacketed cable Up to
1,000’ (304m) using 12 AWG 2-wire jacketed cable

40°F to 90°F (4°C to 32°C)
1°F (0.6°C)
Thermistor network
NEC Class 2
Up to 500’ (152m) using 18 AWG 2-wire jacketed cable Up to
1,000’ (304m) using 12 AWG 2-wire jacketed cable

OVERRIDE ON (10 ma dry switch contact)
OVERRIDE OFF (10 ma dry switch contact)
SUPPLY (10 ma dry switch contact) SNOW (10 ma dry switch
contact) HEAT (10 ma dry switch contact) HIGH TEMP (10 ma
dry switch contact) ALARM (10 ma dry switch contact)

–40°F to 160°F (–40°C to 71°C)
–50°F to 180°F (–45°C to 82°C)