WarmlyYours PD Pro Snow Switch User Manual

Page 12

Advertising
background image

Snow Switch

®

Model PD Pro

Instruction Manual

23735

Rev. B

06/14 (800) 234-4239

http: www.networketi.com

Environmental Technology, Inc.

12 of 30

POWER Cable (provided by customer)

Size for 30 Amp maximum load

SENSOR Wiring

#18 AWG jacketed, 3-conductor

HEATER Cable (provided by customer)

Size to system load

REMOTE Wiring

#22 AWG jacketed, 2-conductor

TEMPERATURE SENSOR ASSEMBLY Wiring

#22 AWG jacketed, 2-conductor

Wire Lead

Connect To:

INPUT Power

(provided by customer)

Line 1

Black

Line 2 / Neutral

White

Ground

Green

OUTPUT To Heater

(provided by customer)

Heater Load 1

Yellow

Heater Load 2

Yellow

Heater Ground (Shield)

Green

Table 2. CABLE RATINGS AND CONNECTIONS.


A representative schematic diagram of an SIT–6E pavement sensor installation is shown below in

Figure 3. Note how the heat tape and other components do not cross.

Figure 3. REPRESENTATIVE SIT–6E PAVEMENT INSTALLATION

SIT–6E Sensor

Heat Tape

Optional

Temperature

Sensor

(Cables Inside

Conduit)

Advertising