Options and accessories – Bryant 581J User Manual

Page 3

Advertising
background image

3

OPTIONS AND ACCESSORIES

FACTORY--INSTALLED OPTIONS (FIOPs)

j

Open protocol controller communicates to

LON, MODBUS, BACNET and Johnson N2 protocols.

j

Through the base connectors for gas and electric

conduit/piping

j

Stainless steel gas heat exchanger (includes tubes,

vestibule plate and collector box)

j

Economizer with dry bulb sensing and barometric

relief

j

Economizer with enthalpy sensing and barometric

relief

j

2 position motorized outdoor air damper

j

Non--fused disconnect

j

Powered 115--volt convenience outlet

j

Non--powered 115--volt convenience outlet

j

High static evaporator fan motor

j

Return Air smoke detector

j

Supply Air smoke detector

j

CO

2

sensor

j

Condenser hail guard -- louvered style

j

Special coating protection for evaporator

and condenser coils

j

Hinged panels for easy unit access

OPTIONAL WARRANTIES

j

Complete Unit Parts only up to 5 years

j

Complete Unit Parts and Labor up to 5 years
Many other optional warranties are available.

See the Commercial Start--Up and Optional Extended

Warranty Price price pages for further information.

FIELD INSTALLED ACCESSORIES

j

Economi$ert IV--electromechanical, gear driven with

Belimo actuator (2--10v DC signal) and controller

j

Economi$ert2--compatible with DDC controls; gear

driven with Belimo actuator (4--20mA) signal and

no controller

j

Power exhaust

j

Two--position motorized outdoor air damper

j

Manual outside air damper 25%

j

Manual outside air damper 50%

j

Roofcurb -- 14 inch (356mm) tall

j

Roofcurb -- 24 inch (610mm) tall

j

Thru--the--bottom connections--electrical only

j

Thru--the--bottom connections--electrical and gas

j

Condenser hail guard -- louvered style

j

Flue shield

j

Flue discharge deflector

j

Liquid propane (LP) conversion kit

j

High altitude conversion kit

j

Phase monitor (loss of phase/phase reversal)

j

Winter start kit, down to 25_F (--4_C)

j

Low ambient head pressure controller,

down to 0_F (--18_C)

j

Low ambient head pressure controller,

down to --20_F (--29_C)

j

Time Guard II compressor anti--cycle protection

j

Return Air smoke detector

j

Supply Air smoke detector

j

Thermostats and Sensors

Economizer Sensors

j

Single Dry bulb control

j

Differential Dry bulb control

j

Single enthalpy control

j

Differential enthalpy control

j

CO

2

-- wall mounted

j

CO

2

-- duct mounted

j

CO

2

-- unit mounted

581J