Energy saver, High e fficiency c ondensing gas water heaters – Bock Water heaters High Efficiency Condensing Gas Water Heaters User Manual

Page 2

Advertising
background image

www.bockwaterheaters.com

110 South Dickinson Street , Madison, Wisconsin 53703

Toll Free 800.794.2491

Phone 608.257.2225

Fax 608.257.5304

80027 Rev 6/08

T&P Valve: Factory Installed

Brass Drain Valve: Factory Installed

Dielectric Fittings: Factory Installed

Magnesium Anode Rods: Factory Installed

Pressures (all): Working Pressure, 150 psi; Tested Pressure, 300 psi

AMP Draw Range: = 1.0 to 1.8 amps and 7.0 amps for 100HEC-399;

115V A.C. required

Warning: Installation on hard surface only. Installation should be in accordance with all national and/or local codes. In the absence of local codes, refer to

NFPA 54 or ANSI Z21.10.1.

Caution: The recommended maximum hot water termperature setting for normal residential use is 120°F. Bock recommends a tempering valve or anti-scald

valve be installed and used according to the manufacturer’s directions to prevent scalding.

NOTE: Diagrams are for both the 60 and 100 gallon models

¾” NPT Gas Inlet

1" NPT Space

Heating Outlet
1" NPT Space

Heating Return

1 ½"NPT Inlet

3" PVC Exhaust

3” PVC Air Inlet

G E

B

D

3" PVC

Exhaust

½” NPT

Condensate

Connection

F

A

C

H

T & P Valve

Cleanout

Drain

B -

28 ¼

Gas Inlet

Exhaust

Air Intake

2 3⁄8”

8 ¼

8 ¼

T & P Valve

1 ½” NPT

Outlet

Determining required vent length

1. Determine the total length of straight vent pipe (in feet) required for both the intake

and the exhaust.

2. Add 5 feet of venting for every 90° elbow.

3. Add 21/2 feet of venting for every 45° elbow.

4. Total vent length cannot exceed "Max Length" in the above chart.

5. Air intake cannot exceed exhaust by more than 30 feet in any venting situation.

Do not include the 3" exhaust elbow or vent terminals in determining maximum

vent length.

Energy Saver

H

igh

E

fficiency

C

ondensing

Gas Water Heaters

This product is available from:

MODEL

NUMBER

DIMENSIONS IN INCHES

A

HT.

B

DIA.

C

HOT

OUT

D

COLD

IN

E

GAS

CONN.

F

FL. TO

VENT

OUTLET

G

FL. TO

AIR

INTAKE

H

FL. TO

T&P

VALVE

WATER

CONN.

DIA.

60 Gallon Models

57

28 1/4

42

13

53 1/2

5

52 1/2

40

1 1/2

100 Gallon Models 77 5/8

28 1/4

63

13

74 3/4

5

74.75

60

1.5

MODEL

NUMBER

STORAGE

(GAL)

RATED

INPUT

(BTUH)

THERMAL

EFF %

1ST HR

DEL GAL.

@ 100° F

RISE

RECOVERY GPH @

DEGREE RISE

MAX 3”

PVC,

ABS &

CPVC

MAX 4”

PVC,

ABS &

CPVC

SHIPPING

WT (LBS)

40° F

100° F 140° F

60HEC-125

60

125,000

96.0%

187

364

145

104

120 ft

170 ft

570

60HEC-150

60

150,000

93.0%

211

423

169

121

100 ft

150 ft

570

60HEC-199

60

199,999

92.0%

265

558

223

159

80 ft

130 ft

900

100HEC-150

100

150,000

99.1%

250

450

180

129

120 ft

170 ft

900

100HEC-199

100

199,999

98.5%

309

597

239

171

100 ft

150 ft

900

100HEC-250

100

250,000

97.0%

364

735

294

210

80 ft

130 ft

900

100HEC-300

100

300,000

92.0%

405

836

335

239

60 ft

110 ft

900

100-HEC-399

100

399,999

93.0%

521

1127

451

322

50 ft

100 ft

900