Bryston External DAC BDA-1 User Manual

Page 2

Advertising
background image

on standby. If neither this LED nor any other LED on the

front panel is illuminated then there is no power entering

the unit or the internal fuse is blown.

See also Remote Trigger

section.

8:

inpUT SiGnAl lED inDicAToRS: There are 8 LEDs to

indicated which input has been selected. The LED will light

green when a PCM signal is present at the selected input,

and red for any other signal present condition, including AC3

multi-channel signals.

9:

AnAloG AUDio oUTpUTS: The BDA-1 is supplied with

one pair of gold plated RCA (phono) jacks for unbalanced

(single-ended) outputs as well as one pair of fully balanced

outputs on XLR male connectors. All connectors are gold

plated and all output signals are fully buffered by Bryston’s

discrete analog audio amplifier stages.

10:

SpDiF oUTpUT: The signal present at the SPDIF output

connector is the same signal that is selected as an input

source. This signal is unaltered except for USB input sig-
nals.

11:

REMoTE TRiGGER inpUT: The BDA-1 is supplied with

a Trigger input put to facilitate remote hard wired on/off

control. A two pin socket mates with the CO110A-11102

bare-wire terminal block connector supplied with your

BDA-1 (

see illustation below-left)

. Supplying a DC control

voltage between 3 and 12 volts (at greater than or equal

to approximately 3mA) will allow you to remotely power

your BDA-1 on or off. The the Remote Trigger input takes

precedence over the front panel push-button switch. If a

valid control voltage is initially applied to the trigger input

when the BDA-1 is already powered on it may be necessary

to toggle the unit OFF-and-ON once, via the Trigger input,

to establish the precedence of the trigger input signal over

the front panel power switch.

12:

DATA plATE: This label provides the units exact model

number, serial number, electrical rating and date of manu-

facture. Do not remove.

13:

RS232 port.

For uploading new software into the BDA-1.

Connects to an RS232 serial port on a computer capable of

running a Windows executable program.

FiRMWARE UpDATES

BDA-1 firmware updates will periodically be available

from Bryston dealers or from Bryston Ltd. directly. These

firmware updates will be supplied as an executable file

(program) which, when executed on your PC, will search

for available serial ports on your computer and then search

for the BDA-1 before uploading and automatically installing

the new firmware in your BDA-1.

1) If the BDA-1 is ON, place it in standby by pressing

the POWER button either on the front panel or

on the remote control. When the LED above the

POWER button lights red, the BDA-1 is in standby.

2) Connect a suitable RS232 cable between your PC

(sorry, but MAC’s are not supported at this time)

and the BDA-1. In most cases (depending on your

BDA1 REAR PANEL:

BDA-1 FRONT PANEL: