Pply the, Ads to a, Positioning the lifter on the load – Wood’s Powr-Grip P2110445DC User Manual

Page 12: Sealing the pads against the load

Advertising
background image

Rev 22.0/5-13

10

P2-04-DC: #35113

In order to be considered clearly audible,

the alarm volume must exceed ambient noise by

at least 15 dBA at the operator position.

3

Since the Maximum Alarm Volume is 103 dBA,

ambient noise must not exceed 88 dBA under any circumstances. Furthermore, if ambient noise
measures 88 dBA, the alarm volume must be set to maximum and the operator must remain
within 2 ft [60 cm] of the warning buzzer, in order for it to be effective.

T

O

A

PPLY THE

P

ADS TO A

L

OAD

Positioning the Lifter on the Load

Make certain that the contact surfaces of the load and all vacuum pads are free of any
contaminates that could prevent the pads from sealing against the load (see MAINTENANCE:

V

ACUUM

P

AD

M

AINTENANCE

). Center the lifter’s rotation axis to within 2" [5 cm] of the load center,

since off-center loading can cause the load to rotate or tilt unexpectedly (see T

O

R

OTATE THE

L

OAD

E

DGEWISE

or T

O

T

ILT THE

L

OAD

to follow), and it may also damage the lifter.

4

Make sure that all

vacuum pads will fit entirely on the load’s contact surface (see SPECIFICATIONS: Maximum Pad
Spread) and that they will be loaded evenly while lifting (see SPECIFICATIONS: Per-Pad Load
Capacity). Then apply the lifter to the load so that all pads are touching the contact surface.

Sealing the Pads against the Load

Firm pressure at the center of the lifter

helps the vacuum pads begin to seal

against the load. Pull the valve
handles for both pad channels outward
until they latch securely in the “APPLY”

position (power on), as shown. This
energizes the vacuum pumps, causing
air to be drawn at the pads

immediately. The red low vacuum warning lights also turn on and remain illuminated until the
lifter attains sufficient vacuum to lift the maximum load weight (see T

O

L

IFT AND

M

OVE THE

L

OAD

:

Load Capacity and the Warning Lights to follow). The valve handles must remain in the “APPLY”
position throughout the entire lift.

WARNING: Keep valve handles latched securely in “APPLY” position throughout

lift.

Note: If a vacuum pad has been lying against a hard object (as during shipping), it may be

slightly distorted. Although initially it may be difficult to apply the pad to a load, this condition
should correct itself with continued use.

3

Consult CE Standard EN 457 for alternative ways to determine whether the alarm is clearly audible to operators.

4

The lifter is designed to handle the maximum load weight (see SPECIFICATIONS: Maximum Load Capacity) when the load’s

center of gravity is positioned within 2" [5 cm] of the lifter’s rotation axis. Occasional loading deviations are permissible,

provided that the operator can maintain control of the load at all times and that the load weight is low enough to avoid damaging
the lifter.

TO APPLY

Advertising
This manual is related to the following products: