Acuum – Wood’s Powr-Grip MT10HV11FDCO User Manual

Page 20

Advertising
background image

Rev 19.0/1-13

18

MT-HV11FDCO: #35093

WARNING: Never use unauthorized rubber cleaners or conditioners to clean

vacuum pad.

To prevent liquid from contaminating the vacuum system during cleaning, cover the suction hole

in the recess for the filter screen or make sure the pad faces downward. Use a clean sponge or
lint-free cloth to apply an authorized cleanser and wipe the pad face clean. A toothbrush (or
similar brush with bristles

that do not harm rubber

) may be used to remove contaminates

clinging to sealing edges.

13

Wipe all residue from the pad face, and allow the pad to dry

completely before using the lifter.

V

ACUUM

T

EST

Test the vacuum system for leakage routinely, as directed in the preceding I

NSPECTION

and

T

ESTING

S

CHEDULES

.

1) Clean the face of each vacuum pad as previously directed (see V

ACUUM

P

AD

M

AINTENANCE

:

Cleaning).

2) Apply the lifter to a clean, smooth, nonporous surface. The surface should be flat or possess

no more curvature than the lifter is designed for (if any).

14

When the pumping cycle is

completed, the vacuum level should register above 16" Hg [-54 kPa] on the vacuum gauge (if

not, see V

ACUUM

S

WITCH

A

DJUSTMENT

to follow).

3) After the vacuum pump stops running, leave the pads attached to the surface and place the

power switch in the OFF ( ) position, to interrupt the energy flow from the battery.

4) Monitor the vacuum gauge:

The vacuum level should not decrease by more than 4" Hg [-14

kPa] in 10 minutes.

WARNING: If lifter fails vacuum test, discontinue use immediately.

Correct any deficiency in the vacuum system before using the lifter. Contact Wood’s Powr-Grip

or an authorized dealer for assistance.

13

If these cleaning methods are not successful, contact Wood’s Powr-Grip or an authorized dealer for assistance.

14

Any test material used must be fully and independently supported, and capable of bearing the lifter’s weight. Do not use the

lifter to lift the test material during the vacuum test.

Advertising