ASSEMBLY

1) Open the shipping container and remove all materials for restraining or protecting the vacuum

lifter. Save the container for use whenever the lifter is transported.

2) Suspend the lifter from a crane as follows: Select hoisting equipment (crane and hoist, when

applicable) rated to carry the maximum load weight plus the lifter weight (see
SPECIFICATIONS: Maximum Load Capacity and Lifter Weight).
Note: Any application of the lifter must conform to all statutory or regulatory standards that

relate to the hoisting equipment when used in its geographical location (eg, relevant OSHA

standards in the USA).

WARNING: Hoisting equipment hook must be fitted with restraining latch to

prevent lift spool from slipping off under any circumstances.

Raise the lift bar of the lifter to a vertical orientation and attach the hoisting equipment hook

to the lift spool.
Note: Some hoisting equipment hooks could interfere with an upright load that extends

beyond the lifter's pad frame. If the load would contact the hook during lifter operation, the

operator must prevent this by attaching a sling (or other rigging that does not interfere with
the load) between the hook and the lift spool.

WARNING: Any sling used must be rated to carry maximum load weight plus

lifter weight.

Use the hoisting equipment to raise the lifter out of the shipping container. Be careful to

avoid damaging any vacuum pads. Remove the pad covers and save them for use whenever
the lifter is stored.

3) Connect the power cable from the lifter to the power source as follows: Wire the female

connector provided to an appropriate current-protected power source (see serial number
plate for power requirements).

WARNING: Wiring must be done by qualified personnel, taking all appropriate

safety precautions.

The power source must be equipped with a ground fault circuit interrupter, in order to reduce

the risk of electrical shocks.

WARNING: Power source must be equipped with ground fault circuit interrupter.

Make certain the power cable is routed so that it does not become tangled while operating

the lifter or hoisting equipment. Then push the power cable’s male connector into the female
connector and twist to secure them together. Now the lifter is operational.

4) Perform Operational and Load Tests for the lifter as directed in MAINTENANCE: T