User Maintenance

A.

General Housekeeping (Continuous).

1. Keep boiler area clear and free of combustible

materials and obstructions to the free flow of
combustion and ventilation air to the boiler.

2. Do not store or use gasoline or other flammable

vapors or liquids in the vicinity of the boiler or any
other appliance.

3. Do not store or use sources of hydrocarbons in

the vicinity of the boiler. Sources of hydrocarbons

include bleaches, cleaners, chemicals, sprays, paint
removers, fabric softeners and refrigerants.

B.

Inspect Concentric Inlet Air/Vent System (Monthly).

1. Concentric Inlet Air/Vent Terminal must be free

of obstruction and undamaged due to impact or

excessive temperature.

2. Concentric Inlet Air/Vent Terminal exterior wall

penetration must be weather tight.

3. Concentric Inlet Air/Vent pipe must be supported at

maximum 5 ft interval and must not sag.

Figure 3: Burner Flame

4. All Concentric external Inlet Air pipe joints must be

secure and airtight.

5. All Concentric internal Vent pipe joints must be

secure, gas tight and watertight.

6. Condensate drain must be free of obstruction and

allow condensate to flow freely. If corrective action

is required, contact your installer or qualified service

agency.

C.

Inspect burner Flames (Monthly).

1. Remove lower front door assembly.
2. Adjust thermostat to the highest setting to initiate

boiler firing.

3. View burner flames through observation glass.
4. Check burner flames. See Figure 3. On high fire

the flame should be stable and mostly blue. No

true yellow tipping should be present, however

intermittent flecks of yellow and orange in the

flame, caused by dust in air, are normal.

WARNING

Service on this boiler should be undertaken only by trained and skilled personnel from a qualified service

agency. Inspections should be performed at intervals specified in Installation, Operating and Service

Instructions and this manual. Maintain manuals in a legible condition.
Keep boiler area clear and free of combustible materials, gasoline and other flammable vapors and liquids.
Do not place any obstructions in boiler room that will hinder flow of combustion and ventilation air.